Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Yokogawa Single Channel Oxygen Analyzer System ZR22/ZR402

    Yokogawa Single Channel Oxygen Analyzer System ZR22/ZR402

    Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

    Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

  • Model AV550G Zirconia Oxygen Analyzer Averaging Converter

    Model AV550G Zirconia Oxygen Analyzer Averaging Converter

    Multi Channel Zirconia Oxygen Analyzer - AV550G The O2mation, model AV550, averaging oxygen analyzer was designed with a focus on practical performance. Yokogawa has refined our expertise in the combustion oxygen business into this new and creative product. It is packed with features designed to minimize plant down ...

  • Multi Channel Oxygen Analyzer System ZR22/AV550G

    Multi Channel Oxygen Analyzer System ZR22/AV550G

    Zirconia Oxygen Probe/Sensor - ZR22 The industry leading ZR22 in-situ type Zirconia detector provides dependable and accurate oxygen measurement. Available in lengths from 15 cm to 5.4 meters, the ZR22 can be used in process temperatures up to 700ºC (up to 1871ºC with our close-coupled extractive adapter ZR22P), and...

  • Model TDLS8000 Tunable Diode Laser Spectrometer

    Model TDLS8000 Tunable Diode Laser Spectrometer

    Yokogawa’s new TDLS8000 houses all of the industry’s leading features in one robust device. The platform design is for in situ measurements which negate the need for sample extraction and conditioning. The non-contacting sensor allows for a variety of process types including corrosive, abrasive and condensing. The firs...

  • Yokogawa Gas Calorimeter - CM6G

    Yokogawa Gas Calorimeter - CM6G

    CM6G-S6100-5R*C,CM6G-S6200-5R*C,CM6G-S6300-5R*C,CM6G-S6400-5R*C,CM6G-S6500-5R*C,CM6G-S6600-5R*C,CM6G-S6700-5R*C,CM6G-S6800-5R*C CM6G-S6110-5R*C,CM6G-S6210-5R*C,CM6G-S6310-5R*C,CM6G-S6410-5R*C,CM6G-S6510-5R*C,CM6G-S6610-5R*C,CM6G-S6710-5R*C,CM6G-S6810-5R*C CM6G-S6100-6R*C,CM6G-S6200-6R*C,CM6G-S6300-6R*C,CM6G-S6400-6R*C,CM6G-S6500-6R*C,CM6G-S6600-6R*C,CM6G-S6700-6R*C,CM6G-S6800-6R*C CM6G-S6110-6R*C,CM6G-S6210-6R*C,CM6G-S6310-6R*C,CM6G-S6410-6R*C,CM6G-S6510-6R*C,CM6G-S6610-6R*C,CM6G-S6710-6R*C,CM6G-S6810-6R*C

    The CM6G Gas Calorimeter is used to measure and control the calorific value or Wobbe Index (WI) of the sample gas. In this calorimeter, the sample gas is burnt at the burner with air and the temperature difference between the combustion exhaust gas and the feed air at the burner inlet is detected by using a thermocoupl...

  • ABB SD823 Power Supply 115/230 V

    ABB SD823 Power Supply 115/230 V

    Power Supply 115/230 V a.c./24 V d.c. 10 A Rated isolation voltage 300 V.

  • ABB SD822 Power Supply 115/230 V

    ABB SD822 Power Supply 115/230 V

    Power Supply 115/230 V a.c./24 V d.c. 5 A Rated isolation voltage 300 V. Also in a G3 compliant version (SD822Z).

  • ABB SD821 Power Supply 115/230 V

    ABB SD821 Power Supply 115/230 V

    Power Supply 115/230 V a.c./24 V d.c. 2.5 A Rated isolation voltage 300 V.

  • ABB AO895 Analog Output 1*8 channels.

    ABB AO895 Analog Output 1*8 channels.

    Analog Output 1*8 channels. 4...20 mA, 12 bit, 0.1% I.S.and HART interface, RL maximum 750 Ohms. Rated isolation voltage 50 V. G3 compliant.

  • ABB AO890  Analog Output 1*8 channels

    ABB AO890 Analog Output 1*8 channels

    Analog Output 1*8 channels. 0…20 mA, 4...20 mA, 12 bit, 0.1% I.S. interface, RL maximum 750 Ohms. Rated isolation voltage 50 V