Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Non-Dispersive Infrared Gas Analyzers (NDIR) IR400
  • Non-Dispersive Infrared Gas Analyzers (NDIR) IR400

Non-Dispersive Infrared Gas Analyzers (NDIR) IR400

2016-05-26 15:42:57

Description:

The IR400 infrared gas analyzer is capable of measuring the concentrations of NO, SO2, CO2, CO, CH4 and O2 components in sample gas. NO, SO2, CO2, CO and CH4 are measured by the non-dispersive infrared method (NDIR), while O2 is measured by built-in paramagnetic sensor or external zirconia sensor. A maximum of 5 components including O2 (up to 4 components except for O2 measurement) are simultaneously measurable. The mass flow type twin detector of high sensitivity and reliability adopted in the infrared ray method detection unit makes the measurement hardly affected by interfering components. In addition, the IR400 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions. Optimum as an analyzer unit of measurement system for combustion exhaust gas from refuse incinerator and boiler, or gas from different industrial furnaces.……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

IR400

The IR400 infrared gas analyzer is capable of measuring the concentrations of NO, SO2, CO2, CO, CH4 and O2 components in sample gas. NO, SO2, CO2, CO and CH4are measured by the non-dispersive infrared method (NDIR), while O2 is measured by built-in paramagnetic sensor or external zirconia sensor. A maximum of 5 components including O2 (up to 4 components except for O2 measurement) are simultaneously measurable.

The mass flow type twin detector of high sensitivity and reliability adopted in the infrared ray method detection unit makes the measurement hardly affected by interfering components. In addition, the IR400 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions.

Optimum as an analyzer unit of measurement system for combustion exhaust gas from refuse incinerator and boiler, or gas from different industrial furnaces.

The highly sensitive and reliable mass flow type twin detector used in the infrared ray method detection block makes measurements much less susceptible to interference from other components. In addition, a microprocessor is built in and a large-size liquid crystal display is equipped for easier operation, higher accuracy and more functions.

This gas analyzer is an ideal system for the measurement of combustion exhaust gas from refuse incinerators and boilers, or gas from various types of industrial furnaces.

  • Measure 5 components including O2 simultaneously and continuously

  • Hardly affected by interference from other gases

  • Equipped with abundant functions

  • Large, easy-to-see LCD unit

  • 19 inch rack mount structure