Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Dissolved Oxygen Sensors DO70G

Dissolved Oxygen Sensors DO70G

2016-05-27 15:01:08

Description:

Dissolved oxygen (DO) is a liquid process measurement for determining the amount of oxygen dissolved or carried in the process liquid. There are three common technologies for dissolved oxygen measurements: polographic, galvanic and optical. The standard units of measure are milligrams per liter (mg/l), parts per million (ppm), parts per billion (ppb), or % saturation.……

New Products

G.M. International X1-IS-AO-02-S I.S. SIL2 HART® Isolating Driver module

G.M. International X1-IS-AO-02-S I.S. SIL2 HART® Isolating Driver module. GMI Intrinsically Safe Isolators, Analog Output

G.M. International D1020S SIL 2 Powered Isolating Driver

G.M. International D1020S SIL 2 Powered Isolating Driver Smart-HART® compatible DIN-Rail. GMI Intrinsically Safe Isolators

G.M. International D1020D SIL 2 Powered Isolating Driver

G.M. International D1020D SIL 2 Powered Isolating Driver Smart-HART® compatible DIN-Rail. GMI Intrinsically Safe Isolators

G.M. International X1-IS-AO-01-S I.S. SIL3 HART® Isolating Driver module

G.M. International X1-IS-AO-01-S I.S. SIL3 HART® Isolating Driver module. GMI Intrinsically Safe Isolators, Analog Output

Assortments

Description

DO70G

DO70G optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effluent activated sludge process.

This optical sensor has a fast response time and good long term stability, and features replaceable sensor cap and cable for easy maintenance. A temperature sensor is incorporated for compensation. The DO70G sensor can be used in either the PB350G/PB360G floating ball holder or in the DOX8HS submersion type holder.

  • A Optical DO sensor that uses a phase measurement method and realizing stable measurements over a long period of time.

  • Measuring range of 0 to 25 mg/l.

  • A sensor cap that is easily replaceable by anyone.

Dissolved Oxygen0 to 25 mg/l (ppm)
Liquid Temperature0 to 50℃
Liquid Pressure0 to 500 kPa
Flow speed20 cm/s or more
Sensor for Temperature Compensation22k NTC
Cable Length3, 5, 10 m
WeightSensor; Approx. 0.1 kg
Cable; 3 m; Approx. 0.4 kg / 5 m; Approx. 0.6 kg / 10 m; Approx. 1.1 kg
Repeatability0.1 mg/l or 3% FS, whichever is greater
Temperature Compensation ErrorWithin ±3% FS for a ±5℃ change in the range of 0 to 40℃
Response TimeWithin 120 sec. (90 % response)