Top Industrial Automation and Electrical Instrument from HKXYTECH
  • High Pressure/ High Temperature Conductivity Sensor SC42/SX42

High Pressure/ High Temperature Conductivity Sensor SC42/SX42

2016-05-27 14:29:35

Description:

High Pressure – High Temperature Contacting sensor primarily designed for Boiler Blowdown and Condensate Leak detection applications. These conductivity cells have extremely high temperature and pressure ratings: the threaded types can handle 16 bar at 200°C and the flanged types can handle 40 bar at 250°C.……

Notice:

New Products

Emerson TREXCHPKL9S1 AMS Trex device communicator

Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPKLWP3S AMS Trex device communicator

Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPKLWP3 AMS Trex device communicator

Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPKLWP1S AMS Trex device communicator

Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Assortments

Description

High Pressure/ High Temperature Conductivity Sensor SC42/SX42

High Pressure – High Temperature Contacting sensor primarily designed for Boiler Blowdown and Condensate Leak detection applications. These conductivity cells have extremely high temperature and pressure ratings: the threaded types can handle 16 bar at 200°C and the flanged types can handle 40 bar at 250°C.

 

Model CodeSC42 Small BoreSX42 Large Bore
Cell Constants0.1/cm; 1.0/cm0.1/cm; 1.0/cm0.1/cm; 1.0/cm
Ranges0.4-2,000 µS/cm; 4.0-5,000 µ/cm0.02-2,000 µS/cm; 0.2-20,000 µS/cm0.02-2,000 µS/cm; 0.2-20,000 µS/cm
Temperature ElementPt1000Pt1000Pt1000
Pressure Rating7 bar/100 PSIG16 bar/ 228 PSIG40 bar/ 570 PSIG
Maximum Temperature100°C/212°Fup to 200°Cup to 250°C
Installation Connections3/4" NPT Fitting; 1", 1.5" or 2" Tri-Clamp1" NPT2" 600lb ANSI Flange
Integral CableNONONO
Materials Of Construction316 Stainless Steel316 Stainless Steel316 Stainless Steel
Design Sytle2-Electrode2-Electrode2-Electrode