Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Non-Dispersive Infrared Gas Analyzers (NDIR) IR200

Non-Dispersive Infrared Gas Analyzers (NDIR) IR200

2016-05-26 15:39:57

Description:

The IR200 infrared gas analyzer is capable of measuring the concentrations of CO2, CO, CH4, SO2, NO and O2 components in sample gas. CO2, CO, CH4, SO2 and NO are measured by the non-dispersive infrared method (NDIR), while O2 is measured by the paramagnetic or zirconia method. A maximum of 4 components including O2 (up to 3 components except for O2 measurement) are simultaneously measurable. A high-sensitivity mass flow sensor is adopted in the detection unit for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, the IR200 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions. This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.……

New Products

Allen-Bradley 20F11NC104JA0NNNNN PowerFlex 753 AC Drive

Allen-Bradley 20F11NC104JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals

Allen-Bradley 20F11NC060JA0NNNNN PowerFlex 753 AC Drive

Allen-Bradley 20F11NC060JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals

Allen-Bradley 20F11NC043JA0NNNNN PowerFlex 753 AC Drive

Allen-Bradley 20F11NC043JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals

Allen-Bradley 20F11NC037JA0NNNNN PowerFlex 753 AC Drive

Allen-Bradley 20F11NC037JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals

Assortments

Description

IR200

The IR200 infrared gas analyzer is capable of measuring the concentrations of CO2, CO, CH4, SO2, NO and O2 components in sample gas. CO2, CO, CH4, SO2 and NO are measured by the non-dispersive infrared method (NDIR), while O2 is measured by the paramagnetic or zirconia method. A maximum of 4 components including O2 (up to 3 components except for O2 measurement) are simultaneously measurable.

A high-sensitivity mass flow sensor is adopted in the detection unit for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, the IR200 has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions.

This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.

A high-sensitivity mass flow sensor is adopted in the detection block for the infrared method. Due to use of a single beam system for measurement, maintenance is easy and excellent stability is ensured for a long period of time. In addition, a microprocessor is built in and a large-size liquid crystal display is provided for easier operation, higher accuracy and more functions.

This analyzer is thus optimum for combustion control of various industrial furnaces, botanical study and global atmospheric research.

  • Simultaneous measurement of 4 components including O2

  • Excellent long-term stability

  • Subdued interference from other gas components

  • Easy to maintain

  • Easy to operate

  • Abundant functions