Description:

Analog models with single rating AC voltage measurement and check live lines such as motive power lines One-touch operation Press-and-lock switch for continuous measurement A wide choice of accessories to meet various testing requirements Vibration - and shock-resistant hand-held compact testers Approx weight including batteries, or Approx. weigh including hard case, handle, test leads and batteries……

Notice:
Standard Accessories Batteries Qty - 8 Handle (B9303XE) Qty - 1 Hard case (B9600HA) Qty - 1 (with leads-housing case) Test lead (B9205VA) Qty - 1 (consist of earth/line terminal) User's manual Qty - 1

New Products

Emerson TREXCHPNAWS3S AMS Trex device communicator

Emerson TREXCHPNAWS3S AMS Trex device communicator, HART Application, Wireless Capability, 3 Years Standard Support, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPNAWS3 AMS Trex device communicator

Emerson TREXCHPNAWS3 AMS Trex device communicator, HART Application, Wireless Capability, 3 Years Standard Support. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPNAWS1S AMS Trex device communicator

Emerson TREXCHPNAWS1S AMS Trex device communicator, HART Application, Wireless Capability, 1 Year Standard Support, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPNAWS1 AMS Trex device communicator

Emerson TREXCHPNAWS1 AMS Trex device communicator, HART Application, Wireless Capability, 1 Year Standard Support. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Assortments

Description

Specifications - Model 321341

Rating100V/20MΩ
Effective Measuring Range0.02–20MΩ
Central Scale Value0.5MΩ
AC Voltage Measurement0 to 150 V
Lower Limit0.1MΩ
Rated Current1 mA
Scale Length88 mm
Approx. Width110 mm
Approx. Height180 mm
Approx. Depth60 mm
Approx. Weight700 g
1.2 kg
BatteriesEight AA (R6P) batteries
Standard AccessoriesBatteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1


Standard Test Conditions - Model 321341

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Specifications - Model 321342

Rating250V/50MΩ
Effective Measuring Range0.05–50MΩ
Central Scale Value1MΩ
AC Voltage Measurement0 to 250 V
Lower Limit0.25MΩ
Rated Current1 mA
Scale Length88 mm
Approx. Width110 mm
Approx. Height180 mm
Approx. Depth60 mm
Approx. Weight700 g
1.2 kg
BatteriesEight AA (R6P) batteries
Standard AccessoriesBatteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1


Standard Test Conditions - Model 321342

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Specifications - Model 321343

Rating500V/100MΩ
Effective Measuring Range0.1–100MΩ
Central Scale Value2MΩ
AC Voltage Measurement0 to 300 V
Lower Limit0.5MΩ
Rated Current1 mA
Scale Length88 mm
Approx. Width110 mm
Approx. Height180 mm
Approx. Depth60 mm
Approx. Weight700 g
1.2 kg
BatteriesEight AA (R6P) batteries
Standard AccessoriesBatteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1


Standard Test Conditions - Model 312343

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Specifications - Model 321344

Rating500V/1000MΩ
Effective Measuring Range1–1000MΩ
Central Scale Value20MΩ
AC Voltage Measurement0 to 300 V
Lower Limit0.5MΩ
Rated Current1 mA
Scale Length88 mm
Approx. Width110 mm
Approx. Height180 mm
Approx. Depth60 mm
Approx. Weight700 g
1.2 kg
BatteriesEight AA (R6P) batteries
Standard AccessoriesBatteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1


Standard Test Conditions - Model 321344

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.


Specifications - Model 321345

Rating1000V/2000MΩ
Effective Measuring Range2–2000MΩ
Central Scale Value50MΩ
AC Voltage Measurement0 to 300 V
Lower Limit1MΩ
Rated Current1 mA
Scale Length88 mm
Approx. Width110 mm
Approx. Height180 mm
Approx. Depth60 mm
Approx. Weight700 g
1.2 kg
BatteriesEight AA (R6P) batteries
Standard AccessoriesBatteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1


Standard Test Conditions - Model 321345

Ambient Temperature/Humidity Ranges23 ±5 /45-75% RH
Position of UseHorizontal (5° max. of angle of inclination)
Battery VoltageWithin effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned ConditionsResistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.
ModelDescription
321341Rating 100V/20MΩ; Effective Measuring Range 0.02–20MΩ; Central Scale Value 0.5MΩ; AC Voltage Measurement 0 to 150 V; Lower Limit 0.1MΩ; Rated Current 1 mA
321342Rating 250V/50MΩ; Effective Measuring Range 0.05-50MΩ; Central Scale Value 1MΩ; AC Voltage Measurement 0 to 250 V; Lower Limit 0.25MΩ; Rated Current 1 mA
321345Rating 1000V/2000MΩ; Effective Measuring Range 2–2000MΩ; Central Scale Value 50MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 1MΩ; Rated Current 1 mA
321343Rating 500V/100MΩ; Effective Measuring Range 0.1–100MΩ; Central Scale Value 2MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 0.5MΩ; Rated Current 1 mA
321344Rating 500V/1000MΩ; Effective Measuring Range 1–1000MΩ; Central Scale Value 20MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 0.5MΩ; Rated Current 1 mA