Yokogawa Analog Input Module AAI135-H00
2016-03-23 12:05:01
Description:
Yokogawa Analog Input Module AAI135-H00,Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules ……
Notice:
Yokogawa Analog Input Module AAI135-H00,Place of Origin: Indonesia, Yokogawa original packing, by carton
New Products
Emerson TREXCHPKL9S1 AMS Trex device communicator
Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3S AMS Trex device communicator
Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3 AMS Trex device communicator
Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP1S AMS Trex device communicator
Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa Analog Input Module AAI135-H00
STANDARD SPECIFICATIONS of AAI135-H00
Current Input Module and Current I/O Module (Isolated Channels)
AAI135, AAI835 The current input module receives signal of 4 to 20 mA, and the current I/O module sends and receives signals of 4 to 20 mA. These modules are isolated between the field and the system as well as in between each channel. They can be used in dual-redundant configuration.
Items | Specifications | |
Model | AAI135 (*1) | AAI835 (*1) |
Number of I/O channels | 8-channel input, isolated channels | 4-channel input/4-channel output, isolated channels |
I/O signal | 4 to 20 mA | Input: 4 to 20 mA; Output: 4 to 20 mA |
Allowable input current | 25 mA | 25 mA |
Withstanding voltage | Between input and system: 500 V AC, for 1 minute Between input channels: 500 V AC, for 1 minute (*2) | Between input/output and system: 500 V AC, for 1 minute Between input/output channels: 500 V AC, for 1 minute (*2) |
Input resistance | Power ON 290 Ω (at 20 mA) to 450 Ω (at 4 mA) (*3) | |
Power OFF 500 kΩ or larger | ||
Allowable load resistance | 0 to 750 Ω (*4) | |
Circuit-open detection | Less than 0.65 mA | |
Accuracy | ±16 μA | Input: ±16 μA Output: ±48 μA |
Data update period | 10 ms | |
Transmitter power supply | 15.0 V or higher (at 20 mA) 29.3 V or less (at 0 mA) (*5) | 15.0 V or higher (at 20 mA) 29.3 V or less (at 0 mA) (*5) |
Temperature drift | ±16 μA/10 °C | |
Maximum current consumption | 360 mA (5 V DC), 450 mA (24 V DC) | 360 mA (5 V DC), 450 mA (24 V DC) |
Weight | 0.3 kg | |
External connection | Pressure clamp terminal, MIL connector cable, dedicated cable (KS1) | |
HART communication (*6) | Available | Available |
Yokogawa Analog Input Module AAI135-H00
EXTERNAL DIMENSIONS of AAI135-H00
Yokogawa Analog Input Module AAI135-H00
MODEL AND SUFFIX CODES AAI135-H00
Description | ||
Model | AAI135 | Analog Input Module (4 to 20 mA, 8-channel, Isolated channels) |
Suffix Codes | -S | Standard type |
-H | With digital communication (HART protocol) | |
5 | With no explosion protection | |
E | With explosion protection | |
0 | Basic type | |
3 | With ISA Standard G3 option and temperature (-20 to 70 °C) option | |
Option Codes | /13A00 | With KS Cable Interface Adapter [Model: ATI3A-00] |
/K4A00 | With KS Cable Interface Adapter [Model: ATK4A-00] | |
/13S00 | With Pressure Clamp Terminal Block for Isolated Analog [Model: ATI3S-00] | |
/13S10 | With Pressure Clamp Terminal Block for Isolated Analog (surge absorber) [Model: ATI3S-10] | |
/13D00 | With Dual Pressure Clamp Terminal Block for Isolated Analog [Model: ATI3D-00] | |
/13D10 | With Dual Pressure Clamp Terminal Block for Isolated Analog (surge absorber) [Model: ATI3D-10] | |
/CCC01 | With Connector Cover for MIL Cable [Model: ACCC01] |
Yokogawa Analog Input Module AAI135-H00