Yokogawa Analog Output Module AAI543-S60
2016-03-22 20:20:49
Description:
Yokogawa Analog Output Module AAI543-S60, Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules ……
Notice:
Yokogawa Analog Output Module AAI543-S60, Place of Origin: Indonesia, Yokogawa original packing, by carton
New Products
Emerson TREXCHPKL9S1 AMS Trex device communicator
Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3S AMS Trex device communicator
Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3 AMS Trex device communicator
Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP1S AMS Trex device communicator
Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa Analog Output Module AAI543-S60
STANDARD SPECIFICATIONS of AAI543-S60
Current/Voltage Input Modules (Non-Isolated)
These modules provide 16 inputs of mainly 4 to 20 mA DC or 1 to 5 V DC standardized signals from 2-wire/4-wire transmitters.
They can be used in dual-redundant configuration.
Current Output Module (Isolated)
AAI543 provides 16 outputs of 4 – 20 mA signal. It can be used in dual-redundant configuration. (*1)
Items | Specifications |
Model | AAI543 |
Number of output channels | 16, isolated, standard switch-over response in redundant configuration (*3) |
Output signal | 4 to 20 mA |
Withstanding voltage | Between output and system: 1500 V AC, for 1 minute (4) |
Allowable load resistance | 0 to 750 Ω |
Circuit-open detection | Less than 0.65 mA |
Accuracy | ±48 μA |
Data update period | 10 ms |
Drift due to ambient temperature change | ±16 μA/10 C |
Maximum current consumption | 230 mA (5 V DC), 540 mA (24 V DC) |
Weight | 0.4 kg |
External communication | Pressure clamp terminal, MIL connector cable, dedicated cable (KS1) |
HART communication (5) | Available |
*1: A dual-redundant configuration is enabled by using two identical modules with the same suffix codes.
*2: When AAI543 is installed in a ER bus node unit, use it in the ambient temperature within 0 to 60 ºC range.
*3: When a switch over from control to stand-by module takes place in the dual-redundant configuration, the maximum period
of time when the field output falls below 4 mA is 100 ms for AAI543-0 (standard switch-over response) and 2 ms for
AAI543-1(fast switch-over response). In case of connecting fast response type field devices, use AAI543-1 (fast
switch-over response) in the dual-redundant configuration.
*4: When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When
the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.
*5: When this module is installed in a ER bus node unit with HART function, the EB401 firmware must be rev. 2 or later.
Yokogawa Analog Output Module AAI543-S60
EXTERNAL DIMENSIONS of AAI543-S60
Yokogawa Analog Output Module AAI543-S60
MODEL AND SUFFIX CODES AAI543-S60
Description | ||
Model | AAI543 | Analog Output Module (4 to 20 mA 16-channel Isolated) |
-S | Standard Type | |
-H | With digital communication (HART protocol) | |
Suffix Codes | 5 | Standard switch-over response in redundant configuration with no explosion protection(*1) |
6 | Fast switch-over response in redundant configuration with no explosion protection(*2) | |
E | Standard switch-over response in redundant configuration with explosion protection(*1) | |
F | Fast switch-over response in redundant configuration with explosion protection(*2) | |
0 | Basic type | |
1 | With ISA Standard G3 option | |
3 | With ISA Standard G3 option and temperature (-20 to 70 C) option | |
Option Codes | /K4A00 | With KS Cable Interface Adapter [Model ATK4A-00] |
/A4S00 | With Pressure Clamp Terminal Block for Analog [Model ATA4S-00] | |
/A4S10 | With Pressure Clamp Terminal Block for Analog (surge absorber) [Model ATA4S-10] | |
/A4D00 | With Dual Pressure Clamp Terminal Block for Analog [Model ATA4D-00] | |
/A4D10 | With Dual Pressure Clamp Terminal Block for Analog (surge absorber) [Model ATA4D-10] | |
/CCC01 | With Connector Cover for MIL Cable [Model ACCC01] |
*1: If “standard switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option and
temperature (-20 to 70 °C) option” may be specified.
*2: If “fast switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option” may be
specified.
Yokogawa Analog Output Module AAI543-S60