Yokogawa Analog Output Module AAI543-S00-hkxytech
  • Yokogawa Analog Output Module AAI543-S00

Yokogawa Analog Output Module AAI543-S00

2016-03-23 11:18:33

Description:

Yokogawa Analog Output Module AAI543-S00, Yokogawa Analog I/O modules function as signal converters; by inputting field analog signals into these modules ……

Notice:
Yokogawa Analog Output Module AAI543-S00, Place of Origin: Indonesia, Yokogawa original packing, by carton

New Products

Emerson TREXCHPNAWS3S AMS Trex device communicator

Emerson TREXCHPNAWS3S AMS Trex device communicator, HART Application, Wireless Capability, 3 Years Standard Support, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPNAWS3 AMS Trex device communicator

Emerson TREXCHPNAWS3 AMS Trex device communicator, HART Application, Wireless Capability, 3 Years Standard Support. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPNAWS1S AMS Trex device communicator

Emerson TREXCHPNAWS1S AMS Trex device communicator, HART Application, Wireless Capability, 1 Year Standard Support, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPNAWS1 AMS Trex device communicator

Emerson TREXCHPNAWS1 AMS Trex device communicator, HART Application, Wireless Capability, 1 Year Standard Support. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Assortments

Description

Yokogawa Analog Output Module AAI543-S00  

  

   STANDARD SPECIFICATIONS of AAI543-S00  

   Current/Voltage Input Modules (Non-Isolated)
   These modules provide 16 inputs of mainly 4 to 20 mA DC or 1 to 5 V DC standardized signals from 2-wire/4-wire transmitters.
  They can be used in dual-redundant configuration.

    

     

      Current Output Module (Isolated)      

     AAI543  provides 16 outputs of 4 – 20 mA signal. It can be used in dual-redundant configuration. (*1)  

 

ItemsSpecifications
ModelAAI543
Number of output channels16, isolated, standard switch-over
response in redundant configuration (*3)
Output signal4 to 20 mA
Withstanding voltageBetween output and system: 1500 V AC, for 1 minute (4)
Allowable load resistance0 to 750 Ω
Circuit-open detectionLess than 0.65 mA
Accuracy±48 μA
Data update period10 ms
Drift due to ambient temperature change±16 μA/10 C
Maximum current consumption230 mA (5 V DC), 540 mA (24 V DC)
Weight0.4 kg
External communicationPressure clamp terminal, MIL connector cable, dedicated cable (KS1)
HART communication (5)Available

  *1: A dual-redundant configuration is enabled by using two identical modules with the same suffix codes.
*2: When AAI543 is installed in a ER bus node unit, use it in the ambient temperature within 0 to 60 ºC range.
*3: When a switch over from control to stand-by module takes place in the dual-redundant configuration, the maximum period
of time when the field output falls below 4 mA is 100 ms for AAI543-0 (standard switch-over response) and 2 ms for
AAI543-1(fast switch-over response). In case of connecting fast response type field devices, use AAI543-1 (fast
switch-over response) in the dual-redundant configuration.
*4: When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When
the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.
*5: When this module is installed in a ER bus node unit with HART function, the EB401 firmware must be rev. 2 or later.

 

 

 Yokogawa Analog Output Module AAI543-S00   

 

EXTERNAL DIMENSIONS of AAI543-S00 

 

 

 Yokogawa Analog Output Module AAI543-S00   

MODEL AND SUFFIX CODES AAI543-S00



Description
ModelAAI543   Analog Output Module (4 to 20 mA 16-channel Isolated)

-SStandard Type

-HWith digital communication (HART protocol)
Suffix
Codes
   5Standard switch-over response in redundant configuration with no explosion protection(*1)

   6Fast switch-over response in redundant configuration with no explosion protection(*2)

   EStandard switch-over response in redundant configuration with explosion protection(*1)

   FFast switch-over response in redundant configuration with explosion protection(*2)

      0Basic type

      1With ISA Standard G3 option

      3With ISA Standard G3 option and temperature (-20 to 70 C) option
Option
Codes
/K4A00With KS Cable Interface Adapter [Model ATK4A-00]

/A4S00With Pressure Clamp Terminal Block for Analog [Model  ATA4S-00]

/A4S10With Pressure Clamp Terminal Block for Analog (surge absorber) [Model ATA4S-10]

/A4D00With Dual Pressure Clamp Terminal Block for Analog [Model ATA4D-00]

/A4D10With Dual Pressure Clamp Terminal Block for Analog (surge absorber) [Model ATA4D-10]

/CCC01With Connector Cover for MIL Cable [Model ACCC01]

 

  *1: If “standard switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option and
temperature (-20 to 70 °C) option” may be specified.
*2: If “fast switch-over response in redundant configuration” is selected, “basic type” or “with ISA Standard G3 option” may be
specified.

 

 

 

 Yokogawa Analog Output Module AAI543-S00