Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS-hkxytech
  • Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS

Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS

2015-11-17 15:59:51

Description:

Intrinsically Safe (IS) Termination Boards Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards recommended for Yokogawa Safety System.……

Notice:

New Products

E+H FMU90-R11CA111AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90

E+H FMU90-R11CA111AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90. Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.

E+H FMU90-R11CA131AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90

E+H FMU90-R11CA131AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90. Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.

E+H FMU90-R11CA212AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90

E+H FMU90-R11CA212AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90. Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.

E+H FMU42-APB2A22A Ultrasonic Sensor, Endress+Hauser Prosonic FMU42

E+H FMU42-APB2A22A Ultrasonic Sensor, Endress+Hauser Prosonic FMU42. Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m.

Assortments

Description

Termination Boards

Special Termination Boards for Yokogawa Prosafe RS

Pepperl+Fuchs provides Intrinsically Safe (IS) and Non Intrinsically Safe (NIS) Termination Boards recommended for Yokogawa Safety System.

Intrinsically Safe (IS) Termination Boards

Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards 


recommended for Yokogawa Safety System.

H-System Termination Boards


We are always pleased to improve our common solutions! 

These Termination Boards are under development.

 

Please use our recommended standard Termination Boards;

Specific project related developments on request!

Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

  Analog input  

SAV144 MB-RS-AI16V-KS-185840

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAV144 MB-RS-S-AI16V-KS-192312

16 plug-in positions. Recommended module KFD2-STC4-Ex1. 24VDC supply voltage. Hazardous area: cage clamp blue terminals. Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-AI16-KS-185838

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-S-RTD16-KS-192299 

16 plug-in positions. Recommended module KFD0-TR-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-S-AI16-KS-192311

16 plug-in positions, Recommended module KFD2-STC4-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

  Analog output  

SAI533 MB-RS-S-AO8-KS-192323

8 plug-in positions, Recommended module KFD2-SCD2-Ex1.LK, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe 


area Yokogawa system connector KS1  

  Digital input  

SDV144 MB-RS-DI16-AKB-185842

8 plug-in positions, Recommended module KFD2-SOT-Ex2, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB  

SDV144 MB-RS-S-DI16-AKB-192319

16 plug-in positions, Recommended module KFD2-SOT2-Ex1.LB, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe 


area Yokogawa system connector AKB  

SDV144 MB-RS-S-DI16-AKB-192325

16 plug-in positions, Recommended module KFD2-SH-Ex1.T.OP (SIL3), 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area 


Yokogawa system connector AKB  

  Digital output  

SDV531 MB-RS-DO8-AKB-185844

8 plug-in positions, Recommended module KFD2-SL2-Ex1, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB  

SDV541 MB-RS-S-DO16-AKB-192321

suitable for 16 pcs. KF-modules, single canal DO KF-module, rated voltage 24 V DC nominal, redundant and fused, power fail monitoring, 


signalling via potential, free relais contact, 2 pcs. system connector (type: AKB), multipole 50 pin, screw terminals for field wiring, 2,5mm² via 


KF-module, label carrier as an option, recommended module KFD2-SL2-Ex1


Non Intrinsically Safe (NIS) Termination Boards

Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

Analog input

SAI143 TB-RS-AI16-KS-186102

2 terminals/ signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1

SAV144 TB-RS-AI16V-KS-183383

3 terminals/ signal (active/ passive transmitters), Each signal fused on board Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for KS1

SAI143 TB-YRS-R2-AIC16FL-KS-SC-227110

supported field devices: 2- and 3-wire-sensors, active, voltage source, rated voltage 24 V DC nominal, fused, power fail monitoring, signalling 


via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 40-pin, screw terminals for field wiring, 


2,5mm², dimensions (whd): 156x155x90mm

Analog output

SAI533 TB-RS-AO8-KS-205527

2 terminals /signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1

Digital input

SDV144 TB-RS-DI16-AKB-185847

3 terminals/ signal (contact/ proximity switch), 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for AKB

ADV144 TB-YRS-R2-DIX16FS-AK-SP-214386

supported field devices: 3-wire-sensor, potential free contact, active voltage source, rated voltage 24 V DC nominal, fused, power fail 


monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 50-pin, scrimp clamp 


terminals for field wiring, 2,5mm², dimensions (whd): 214x126x90mm

Digital output

SDV531 TB-RS-DO8-AKB-185849

2 terminals /signal, 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB

SDV541 TB-RS-DO16-AKB-204061

2 terminals/ signal, 24VDC supply voltage, 16 channels, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB

SDV521 TB-YRS-R2-DO04FS-AK-SC-224747

supported field devices: lamps, valves, resistors, DO: 24VDC/2,0A per channel, Rated voltage 24 V DC nominal, redundant and fused, power 


fail monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: AKB), multipole 50-pin, screw terminals 


for field wiring, 2,5mm², dimensions (whd): 114x155x90mm