Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS

Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS

2015-11-17 15:59:51

Description:

Intrinsically Safe (IS) Termination Boards Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards recommended for Yokogawa Safety System.……

New Products

Orbinox VG SERIES 61 Slurry knife gate valve

Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.

Crosby J-Series Direct Spring Pressure Relief Valves

J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.

Vanessa Series 30,000 Cryogenic Triple Offset Valve

The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.

Sempell Model SOT High pressure steam safety valve

The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.

Assortments

Description

Termination Boards

Special Termination Boards for Yokogawa Prosafe RS

Pepperl+Fuchs provides Intrinsically Safe (IS) and Non Intrinsically Safe (NIS) Termination Boards recommended for Yokogawa Safety System.

Intrinsically Safe (IS) Termination Boards

Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards 


recommended for Yokogawa Safety System.

H-System Termination Boards


We are always pleased to improve our common solutions! 

These Termination Boards are under development.

 

Please use our recommended standard Termination Boards;

Specific project related developments on request!

Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

  Analog input  

SAV144 MB-RS-AI16V-KS-185840

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAV144 MB-RS-S-AI16V-KS-192312

16 plug-in positions. Recommended module KFD2-STC4-Ex1. 24VDC supply voltage. Hazardous area: cage clamp blue terminals. Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-AI16-KS-185838

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-S-RTD16-KS-192299 

16 plug-in positions. Recommended module KFD0-TR-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-S-AI16-KS-192311

16 plug-in positions, Recommended module KFD2-STC4-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

  Analog output  

SAI533 MB-RS-S-AO8-KS-192323

8 plug-in positions, Recommended module KFD2-SCD2-Ex1.LK, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe 


area Yokogawa system connector KS1  

  Digital input  

SDV144 MB-RS-DI16-AKB-185842

8 plug-in positions, Recommended module KFD2-SOT-Ex2, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB  

SDV144 MB-RS-S-DI16-AKB-192319

16 plug-in positions, Recommended module KFD2-SOT2-Ex1.LB, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe 


area Yokogawa system connector AKB  

SDV144 MB-RS-S-DI16-AKB-192325

16 plug-in positions, Recommended module KFD2-SH-Ex1.T.OP (SIL3), 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area 


Yokogawa system connector AKB  

  Digital output  

SDV531 MB-RS-DO8-AKB-185844

8 plug-in positions, Recommended module KFD2-SL2-Ex1, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB  

SDV541 MB-RS-S-DO16-AKB-192321

suitable for 16 pcs. KF-modules, single canal DO KF-module, rated voltage 24 V DC nominal, redundant and fused, power fail monitoring, 


signalling via potential, free relais contact, 2 pcs. system connector (type: AKB), multipole 50 pin, screw terminals for field wiring, 2,5mm² via 


KF-module, label carrier as an option, recommended module KFD2-SL2-Ex1


Non Intrinsically Safe (NIS) Termination Boards

Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

Analog input

SAI143 TB-RS-AI16-KS-186102

2 terminals/ signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1

SAV144 TB-RS-AI16V-KS-183383

3 terminals/ signal (active/ passive transmitters), Each signal fused on board Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for KS1

SAI143 TB-YRS-R2-AIC16FL-KS-SC-227110

supported field devices: 2- and 3-wire-sensors, active, voltage source, rated voltage 24 V DC nominal, fused, power fail monitoring, signalling 


via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 40-pin, screw terminals for field wiring, 


2,5mm², dimensions (whd): 156x155x90mm

Analog output

SAI533 TB-RS-AO8-KS-205527

2 terminals /signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1

Digital input

SDV144 TB-RS-DI16-AKB-185847

3 terminals/ signal (contact/ proximity switch), 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for AKB

ADV144 TB-YRS-R2-DIX16FS-AK-SP-214386

supported field devices: 3-wire-sensor, potential free contact, active voltage source, rated voltage 24 V DC nominal, fused, power fail 


monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 50-pin, scrimp clamp 


terminals for field wiring, 2,5mm², dimensions (whd): 214x126x90mm

Digital output

SDV531 TB-RS-DO8-AKB-185849

2 terminals /signal, 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB

SDV541 TB-RS-DO16-AKB-204061

2 terminals/ signal, 24VDC supply voltage, 16 channels, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB

SDV521 TB-YRS-R2-DO04FS-AK-SC-224747

supported field devices: lamps, valves, resistors, DO: 24VDC/2,0A per channel, Rated voltage 24 V DC nominal, redundant and fused, power 


fail monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: AKB), multipole 50-pin, screw terminals 


for field wiring, 2,5mm², dimensions (whd): 114x155x90mm