Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS

Pepperl+Fuchs Termination Boards Special Termination Boards for Yokogawa Prosafe RS

2015-11-17 15:59:51

Description:

Intrinsically Safe (IS) Termination Boards Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards recommended for Yokogawa Safety System.……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Termination Boards

Special Termination Boards for Yokogawa Prosafe RS

Pepperl+Fuchs provides Intrinsically Safe (IS) and Non Intrinsically Safe (NIS) Termination Boards recommended for Yokogawa Safety System.

Intrinsically Safe (IS) Termination Boards

Pepperl+Fuchs offers systems for different applications and mountings. Please have a look at our H-System and K-System Termination Boards 


recommended for Yokogawa Safety System.

H-System Termination Boards


We are always pleased to improve our common solutions! 

These Termination Boards are under development.

 

Please use our recommended standard Termination Boards;

Specific project related developments on request!

Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

  Analog input  

SAV144 MB-RS-AI16V-KS-185840

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAV144 MB-RS-S-AI16V-KS-192312

16 plug-in positions. Recommended module KFD2-STC4-Ex1. 24VDC supply voltage. Hazardous area: cage clamp blue terminals. Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-AI16-KS-185838

8 plug-in positions, Recommended module KFD2-STC4-Ex2, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-S-RTD16-KS-192299 

16 plug-in positions. Recommended module KFD0-TR-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

SAI143 MB-RS-S-AI16-KS-192311

16 plug-in positions, Recommended module KFD2-STC4-Ex1, 24VDC supply voltage, Hazardous area: cage clamp blue terminals, Safe area 


Yokogawa system connector for KS1  

  Analog output  

SAI533 MB-RS-S-AO8-KS-192323

8 plug-in positions, Recommended module KFD2-SCD2-Ex1.LK, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe 


area Yokogawa system connector KS1  

  Digital input  

SDV144 MB-RS-DI16-AKB-185842

8 plug-in positions, Recommended module KFD2-SOT-Ex2, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB  

SDV144 MB-RS-S-DI16-AKB-192319

16 plug-in positions, Recommended module KFD2-SOT2-Ex1.LB, 24VDC supply voltage, redundant, Hazardous area: screw blue terminals, Safe 


area Yokogawa system connector AKB  

SDV144 MB-RS-S-DI16-AKB-192325

16 plug-in positions, Recommended module KFD2-SH-Ex1.T.OP (SIL3), 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area 


Yokogawa system connector AKB  

  Digital output  

SDV531 MB-RS-DO8-AKB-185844

8 plug-in positions, Recommended module KFD2-SL2-Ex1, 24VDC supply voltage, Hazardous area: screw blue terminals, Safe area Yokogawa 


system connector AKB  

SDV541 MB-RS-S-DO16-AKB-192321

suitable for 16 pcs. KF-modules, single canal DO KF-module, rated voltage 24 V DC nominal, redundant and fused, power fail monitoring, 


signalling via potential, free relais contact, 2 pcs. system connector (type: AKB), multipole 50 pin, screw terminals for field wiring, 2,5mm² via 


KF-module, label carrier as an option, recommended module KFD2-SL2-Ex1


Non Intrinsically Safe (NIS) Termination Boards

Yokogawa IO Card Adaptable Pepperl+Fuchs Product Product Data

Analog input

SAI143 TB-RS-AI16-KS-186102

2 terminals/ signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1

SAV144 TB-RS-AI16V-KS-183383

3 terminals/ signal (active/ passive transmitters), Each signal fused on board Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for KS1

SAI143 TB-YRS-R2-AIC16FL-KS-SC-227110

supported field devices: 2- and 3-wire-sensors, active, voltage source, rated voltage 24 V DC nominal, fused, power fail monitoring, signalling 


via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 40-pin, screw terminals for field wiring, 


2,5mm², dimensions (whd): 156x155x90mm

Analog output

SAI533 TB-RS-AO8-KS-205527

2 terminals /signal, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for KS1

Digital input

SDV144 TB-RS-DI16-AKB-185847

3 terminals/ signal (contact/ proximity switch), 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system 


connector for AKB

ADV144 TB-YRS-R2-DIX16FS-AK-SP-214386

supported field devices: 3-wire-sensor, potential free contact, active voltage source, rated voltage 24 V DC nominal, fused, power fail 


monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: YOKOGAWA), multipole 50-pin, scrimp clamp 


terminals for field wiring, 2,5mm², dimensions (whd): 214x126x90mm

Digital output

SDV531 TB-RS-DO8-AKB-185849

2 terminals /signal, 24VDC supply voltage, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB

SDV541 TB-RS-DO16-AKB-204061

2 terminals/ signal, 24VDC supply voltage, 16 channels, Field area: Pressure clamp terminals, DCS area Yokogawa system connector for AKB

SDV521 TB-YRS-R2-DO04FS-AK-SC-224747

supported field devices: lamps, valves, resistors, DO: 24VDC/2,0A per channel, Rated voltage 24 V DC nominal, redundant and fused, power 


fail monitoring, signalling via potential free relais contact, 2 pcs. system connector redundant (type: AKB), multipole 50-pin, screw terminals 


for field wiring, 2,5mm², dimensions (whd): 114x155x90mm