
Yokogawa Coriolis Mass Flowmeters - ROTAMASS 3-Series
2015-06-29 16:35:26
Description:
ROTAMASS is the integral and remote type Coriolis Mass Flowmeter. Both types have highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved.……
Notice:
New Products
Allen-Bradley 25B-V4P8N104 PowerFlex 525 low voltage AC drives - Rockwell
Allen-Bradley 25B-V4P8N104 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 120 VAC, 1 Phase, 4.8 Amps, 1.0 HP, 0.75 kW Normal Duty; 1.0 HP, 0.75 kW Heavy Duty, Frame B, IP20 NEMA / Open Type, No Filter.
Allen-Bradley 25B-V6P0N104 PowerFlex 525 low voltage AC drives - Rockwell
Allen-Bradley 25B-V6P0N104 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 120 VAC, 1 Phase, 6 Amps, 1.5 HP, 1.1 kW Normal Duty; 1.5 HP, 1.1 kW Heavy Duty, Frame B, IP20 NEMA / Open Type, No Filter.
Allen-Bradley 25B-D4P0N114 PowerFlex 525 low voltage AC drives - Rockwell
Allen-Bradley 25B-D4P0N114 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 480 VAC, 3 Phase, 4 Amps, 2 HP, 1.5 kW Normal Duty; 2 HP, 1.5 kW Heavy Duty, Frame A, IP20 NEMA / Open Type, Filter.
Allen-Bradley 25B-D6P0N104 PowerFlex 525 low voltage AC drives - Rockwell
Allen-Bradley 25B-D6P0N104 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 480 VAC, 3 Phase, 6 Amps, 3 HP, 2.2 kW Normal Duty; 3 HP, 2.2 kW Heavy Duty, Frame A, IP20 NEMA / Open Type, No Filter.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Specifications
Accurate and stable mass flow measurement is achieved.
Coriolis Mass Flowmeters - ROTAMASS 3-Series
ROTAMASS is the integral and remote type Coriolis Mass Flowmeter. Both types have highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved. ROTAMASS employs a flame-proof type converter case suitable for use in the hazardous area together with its intrinsically safety type detector. ROTAMASS's signal processing, housing protection and its detector's special decoupling system against external loads and vibrations, realize high performance in real applications. |
Supports HART, FOUNDATION™ fieldbus, Modbus |
Features
- | Field transmitter for nearly all fluids |
- | Refined digital signal processing enables accurate and stable measurement |
- | High accuracy and high stability over a wide range |
- | A special detector coupling system makes the device highly independent from external loads or vibrations |
- | Wide temperature range -200 deg C to 350 deg C |
Specifications
- | Refined digital signal processing enables accurate and stable measurement |
- | Simple flow path means self-draining, food capable and simple to clean |
- | High accuracy and high stability over a wide range |
- | Accurate density measurement, up to +/- 0.5 g/l |
- | Two analog outputs, 2 pulse outputs or status-out and one status-in as standard I/O |
- | Available in Explosion Proof versions |
- | Wide temperature range -200 deg C to 350 deg C |
- | Microprocessor-based multifunction capability |
- | EEPROM protects parameter settings and totalized values |
- | During power failure of any duration |
- | High visibly LCD display |
- | HART communication function |
- | FOUNDATION™ fieldbus communication as an option |
- | Modbus communication as an option |
- | Intrinsically safe outputs as an option |
- | Several tube materials available |
- | EN or ANSI flanges as standard |
- | Other process connections on request |