Top Industrial Automation and Electrical Instrument from HKXYTECH
  • G.M. International D5212Q Intrinsically Safe Isolators - Analog Input

G.M. International D5212Q Intrinsically Safe Isolators - Analog Input

2025-12-09 15:12:49

Description:

G.M. International D5212Q Intrinsically Safe Isolators - Analog Input. I.S. SIL2 2/4-Wire Transmitter Power Supply.……

G.M. International Intrinsically Safe Isolators

New Products

G.M. International X1-IS-AI-01-S Intrinsically Safe Isolators

G.M. International X1-IS-AI-01-S Intrinsically Safe Isolators. I.S. SIL3 2-Wire Passive/Active HART® Tx Current Repeater.

G.M. International X1-IS-AI-01-S Intrinsically Safe Isolators

G.M. International X1-IS-AI-01-S Intrinsically Safe Isolators. I.S. SIL3 2-Wire Passive/Active HART® Tx Current Repeater.

G.M. International X1-IS-AI-02-S Intrinsically Safe Isolators

G.M. International X1-IS-AI-02-S Intrinsically Safe Isolators. I.S. SIL2 2-Wire Passive/Active HART® Tx Current Repeater.

G.M. International D5020D I.S. SIL2 HART® Isolating Driver

G.M. International D5020D I.S. SIL2 HART® Isolating Driver. GMI Intrinsically Safe Isolators, Analog Output, Discover D5000

Assortments

Description

G.M. International D5212Q Intrinsically Safe Isolators - Analog Input. I.S. SIL2 2/4-Wire Transmitter Power Supply.

The Repeater Power Supply D5212 module is a high integrity analog input interface suitable for applications requiring SIL 2 level in safety related systems for high risk industries. It provides a fully floating dc supply for energizing conventional 2 wires 0/4-20 mA, active or passive, transmitters located in Hazardous Area, and repeats the current in floating circuit to drive Safe Area loads. The module is fully configurable to achieve input/output multiplexing, scaling, duplication, inversion, and input elaboration (addition, subtraction, low/high selection). An additional alarm contact can be (de-)activated on programmable input trip points, including hysteresis and delays. Configuration and diagnostic parameters are programmable and can also be monitored/set through Modbus.

FEATURES

  • SIL 2 / SC 3

  • Input from Zone 0/Div. 1

  • Installation in Zone 2/Div. 2

  • 0/4-20 mA Active-Passive Input, Source Output

  • Duplication/inversion/scaling output

  • Input operations (sum, dif, max, min) available

  • Input and Output short circuit proof

  • Out of range fault detection

  • Alarm output with user-settable trip points

  • Modbus RTU RS-485 for monitor & configuration

  • Fully programmable operating parameters

  • High Accuracy, µP controlled A/D converter

  • Three port isolation, Input / Output / Supply

  • High Density, four channels per unit

STATUS

ACTIVE


G.M. International Intrinsically Safe Isolators

GMI D5011D
GMI D5011S
GMI D5014D
GMI D5014S
GMI D5015SK
GMI D5015SS
GMI D5016DK
GMI D5016DS
GMI D5016SK
GMI D5016SS
GMI D5212Q
GMI D5254S
GMI X1-IS-AI-01-S
GMI X1-IS-AI-02-S
GMI D1010D
GMI D1010D-046
GMI D1010S
GMI D1010S-046
GMI D1012Q
GMI D1014D
GMI D1014S
GMI D1010S-054
GMI D1010S-056
GMI D1010S-057
GMI D1052D
GMI D1052S
GMI D1052X
GMI D1052Y
GMI D1053S
GMI D1054S
GMI D1022D
GMI D1022S
GMI D5020D
GMI D5020S
GMI X1-IS-AO-01-S
GMI X1-IS-AO-02-S
GMI D1020D
GMI D1020S
GMI D1130D
GMI D1130S
GMI D5030D
GMI D5030S
GMI D5031D
GMI D5031S
GMI D5032D
GMI D5032S
GMI D5034D
GMI D5034S
GMI D5036D
GMI D5036S
GMI D5037D
GMI D5037S
GMI D5038DA
GMI D5038DB
GMI D5038DC
GMI D5038DD
GMI D5038SA
GMI D5038SB
GMI D5038SC
GMI D5038SD
GMI D5038XA
GMI D5038XB
GMI D5038XC
GMI D5038XD
GMI D5231E
GMI D5232Q
GMI D5233Q
GMI X1-IS-DI-01-S
GMI X1-IS-DI-02-S
GMI X1-IS-DI-03-S
GMI X1-IS-DI-04-S
GMI D1030D
GMI D1030S
GMI D1031D
GMI D1031Q
GMI D1032D
GMI D1032Q
GMI D1033D
GMI D1033Q
GMI D1034D
GMI D1034S
GMI D1080D
GMI D1081D
GMI D1180D
GMI D1046Y
GMI D5040D
GMI D5040S
GMI D5048S
GMI D5049S
GMI D5240T
GMI X1-IS-DO-01-S
GMI X1-IS-DO-02-S
GMI D1040Q
GMI D1041Q
GMI D1042Q
GMI D1043Q
GMI D1044D
GMI D1044S
GMI D1045Y
GMI D1048S
GMI D1049S