Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Yokogawa Field Control Unit AFV10D
  • Yokogawa Field Control Unit AFV10D

Yokogawa Field Control Unit AFV10D

2015-06-26 11:35:51

Description:

Yokogawa Field Control Unit AFV10D Field Control Unit (FCU) which is the processor of the Field Control Station (FCS).……

Notice:
EXW China Term; Coutry of Origin: Singapore;

New Products

Emerson TREXCHPKL9S1 AMS Trex device communicator

Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPKLWP3S AMS Trex device communicator

Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPKLWP3 AMS Trex device communicator

Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Emerson TREXCHPKLWP1S AMS Trex device communicator

Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.

Assortments

Description

Yokogawa Field Control Unit AFV10D

 

Yokogawa Field Control Unit AFV10D  HARDWARE SPECIFICATIONS

 

Processor: VR5432 (133 MHz);

Main Memory Capacity: 32 Mbyte

Memory Protection During Power Failure: Battery
  Battery Back-up for Main Memory: Max. 72 hours
  Battery Recharge Time: Min. 48 hours

 

FCU Status Contact Output : 2 terminals (NC, C)
Contact Points open during FCU failure
Contact Rating: 30 V DC, max. 0.3 A

 

Communication Interface: Vnet/IP Interface: Dual-redundant

 

Vnet/IP Communication Speed: 1 Gbps Full Duplex

 

Connection Specifications: 
Cable: CAT5e (Enhanced Category 5 cable) or better, UTP
Transmission: 1000BASE-T compliance
Connector: RJ45 connector
Max. distance: 100 m (Distance between AFV10 and Layer 2 switch)

 

No. of Node Units Connectable:
Max. 14/FCU
The total number of the local and remote nodes that can be connected to FCU are 14 or less. (The local nodes: 9 or less)
LFS1500 allows up to 3 modes, and can be expanded to 14 if LFS1530 Application capacity
Expansion Package (for AFV10) is added.

 

No. of I/O Modules: Max. 8

 

Local Node Connection:
When connecting a Local Node to FCU, install ESB Bus Coupler Module (EC401) on FCU.
EC401 must be installed in slot 7 or slot 8. To make single configuration, EC401 must be installed in slot 7, and Slot 8 must be empty.

 

Remote Node Connection
When connecting a Remote Node to FCU, install ER Bus Interface Master Module (EB401) on FCU.
To make single configuration, EB401 must be installed in an odd-number slot, and keep empty the right side of the installed EB401.

Power Supply: (specify with Suffix Codes)
Voltage: 100-120 V AC, Frequency: 50/60 Hz
Voltage: 220-240 V AC, Frequency: 50/60 Hz
Voltage: 24 V DC

 

Power Consumption
100-120 V AC: 200 VA
220-240 V AC: 230 VA
24 V DC: 5.5 A

 

Weight:
Approx. 7 kg (AFV10S)
Approx. 8 kg (AFV10D)

 

Mounting:
19" Rack Mounting:
Rack mount (8 x M5 screws)
Insulation bush (accessory)

 

Connection
Power Supply: M4 screw terminal connection
Grounding: M4 screw terminal connection
Contact Output: M4 screw terminal connection
Network: Connect CAT5e (Enhanced Category 5 cable) to Layer 2 switch.

 

Yokogawa Field Control Unit AFV10D  HARDWARE SPECIFICATIONS

 

 

Yokogawa Field Control Unit AFV10D

 

 

 

MODELS AND SUFFIX CODES ( Field Control Unit (19 Rack Mountable Type) )

 



Description
ModelAFV10DDuplexed Field Control Unit (for Vnet/IP, for FIO, for 19” Rack Mountable)

-SStandard type

    4Dual-Redundant Vnet/IP, Dual-Redundant power supply

      1Always 1

         1100–120 V AC power supply
Suffix Codes         2220–240 V AC power supply

         424 V DC power supply

           5Basic type with no explosion protection

           6With ISA Standard G3 option and no explosion protection

           EBasic type with explosion protection

           FWith ISA Standard G3 option and explosion protection

               1 LFS1500 Basic software license for Control Function for Basic Field Control Unit
(for FIO, for Vnet/IP)
Option Code/ATDOCExplosion Protection Manual (1)

 

1 Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres

AFV30S Field Control Unit (for FIO, 19-inch Rack Mountable)

AFV30S-S41252, AFV30S-S41252/HKU, AFV30S-S41252/ATDOC

AFV30S-S41262, AFV30S-S41262/HKU, AFV30S-S41262/ATDOC

AFV30S-S412E2, AFV30S-S412E2/HKU, AFV30S-S412E2/ATDOC

AFV30S-S412F2, AFV30S-S412F2/HKU, AFV30S-S412F2/ATDOC

AFV30S-S41152, AFV30S-S41152/HKU, AFV30S-S41152/ATDOC

AFV30S-S41162, AFV30S-S41162/HKU, AFV30S-S41162/ATDOC

AFV30S-S411E2, AFV30S-S411E2/HKU, AFV30S-S411E2/ATDOC

AFV30S-S411F2, AFV30S-S411F2/HKU, AFV30S-S411F2/ATDOC

AFV30S-S41452, AFV30S-S41452/HKU, AFV30S-S41452/ATDOC

AFV30S-S41462, AFV30S-S41462/HKU, AFV30S-S41462/ATDOC

AFV30S-S414E2, AFV30S-S414E2/HKU, AFV30S-S414E2/ATDOC

AFV30S-S414F2, AFV30S-S414F2/HKU, AFV30S-S414F2/ATDOC

 

AFV30S-S31252, AFV30S-S31252/HKU, AFV30S-S31252/ATDOC

AFV30S-S31262, AFV30S-S31262/HKU, AFV30S-S31262/ATDOC

AFV30S-S312E2, AFV30S-S312E2/HKU, AFV30S-S312E2/ATDOC

AFV30S-S312F2, AFV30S-S312F2/HKU, AFV30S-S312F2/ATDOC

AFV30S-S31152, AFV30S-S31152/HKU, AFV30S-S31152/ATDOC

AFV30S-S31162, AFV30S-S31162/HKU, AFV30S-S31162/ATDOC

AFV30S-S311E2, AFV30S-S311E2/HKU, AFV30S-S311E2/ATDOC

AFV30S-S311F2, AFV30S-S311F2/HKU, AFV30S-S311F2/ATDOC

AFV30S-S31452, AFV30S-S31452/HKU, AFV30S-S31452/ATDOC

AFV30S-S31462, AFV30S-S31462/HKU, AFV30S-S31462/ATDOC

AFV30S-S314E2, AFV30S-S314E2/HKU, AFV30S-S314E2/ATDOC

AFV30S-S314F2, AFV30S-S314F2/HKU, AFV30S-S314F2/ATDOC 

 

AFV30D Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable)

AFV30D-S41252, AFV30D-S41252/HKU, AFV30D-S41252/ATDOC

AFV30D-S41262, AFV30D-S41262/HKU, AFV30D-S41262/ATDOC

AFV30D-S412E2, AFV30D-S412E2/HKU, AFV30D-S412E2/ATDOC

AFV30D-S412F2, AFV30D-S412F2/HKU, AFV30D-S412F2/ATDOC

AFV30D-S41152, AFV30D-S41152/HKU, AFV30D-S41152/ATDOC

AFV30D-S41162, AFV30D-S41162/HKU, AFV30D-S41162/ATDOC

AFV30D-S411E2, AFV30D-S411E2/HKU, AFV30D-S411E2/ATDOC

AFV30D-S411F2, AFV30D-S411F2/HKU, AFV30D-S411F2/ATDOC

AFV30D-S41452, AFV30D-S41452/HKU, AFV30D-S41452/ATDOC

AFV30D-S41462, AFV30D-S41462/HKU, AFV30D-S41462/ATDOC

AFV30D-S414E2, AFV30D-S414E2/HKU, AFV30D-S414E2/ATDOC

AFV30D-S414F2, AFV30D-S414F2/HKU, AFV30D-S414F2/ATDOC

 

AFV40S Field Control Unit (for FIO, with Cabinet)

AFV40S-S41102,AFV40S-41102/ATDOC,AFV40S-S41102/CH,AFV40S-41102/CE

AFV40S-S41202,AFV40S-41202/ATDOC,AFV40S-S41202/CH,AFV40S-41202/CE

AFV40S-S41402,AFV40S-41402/ATDOC,AFV40S-S41402/CH,AFV40S-41402/CE

 

AFV40S-S42102,AFV40S-42102/ATDOC,AFV40S-S42102/CH,AFV40S-42102/CE

AFV40S-S42202,AFV40S-42202/ATDOC,AFV40S-S42202/CH,AFV40S-42202/CE

AFV40S-S42402,AFV40S-42402/ATDOC,AFV40S-S42402/CH,AFV40S-42402/CE

AFV40S-S43102,AFV40S-43102/ATDOC,AFV40S-S43102/CH,AFV40S-43102/CE

AFV40S-S43202,AFV40S-43202/ATDOC,AFV40S-S43202/CH,AFV40S-43202/CE

AFV40S-S43402,AFV40S-43402/ATDOC,AFV40S-S43402/CH,AFV40S-43402/CE

AFV40S-S44102,AFV40S-44102/ATDOC,AFV40S-S44102/CH,AFV40S-44102/CE

AFV40S-S44202,AFV40S-44202/ATDOC,AFV40S-S44202/CH,AFV40S-44202/CE

AFV40S-S44402,AFV40S-44402/ATDOC,AFV40S-S44402/CH,AFV40S-44402/CE


AFV40S-S31102,AFV40S-41102/ATDOC,AFV40S-S31102/CH,AFV40S-41102/CE

AFV40S-S31202,AFV40S-41202/ATDOC,AFV40S-S31202/CH,AFV40S-41202/CE

AFV40S-S31402,AFV40S-41402/ATDOC,AFV40S-S31402/CH,AFV40S-41402/CE

AFV40S-S32102,AFV40S-42102/ATDOC,AFV40S-S32102/CH,AFV40S-42102/CE

AFV40S-S32202,AFV40S-42202/ATDOC,AFV40S-S32202/CH,AFV40S-42202/CE

AFV40S-S32402,AFV40S-42402/ATDOC,AFV40S-S32402/CH,AFV40S-42402/CE

AFV40S-S33102,AFV40S-43102/ATDOC,AFV40S-S33102/CH,AFV40S-43102/CE

AFV40S-S33202,AFV40S-43202/ATDOC,AFV40S-S33202/CH,AFV40S-43202/CE

AFV40S-S33402,AFV40S-43402/ATDOC,AFV40S-S33402/CH,AFV40S-43402/CE

AFV40S-S34102,AFV40S-44102/ATDOC,AFV40S-S34102/CH,AFV40S-44102/CE

AFV40S-S34202,AFV40S-44202/ATDOC,AFV40S-S34202/CH,AFV40S-44202/CE

AFV40S-S34402,AFV40S-44402/ATDOC,AFV40S-S34402/CH,AFV40S-44402/CE

 

AFV40D Duplexed Field Control Unit (for FIO, with Cabinet)

AFV40D-S421102, AFV40D-421102/ATDOC, AFV40D-S421102/CH, AFV40D-421102/CE

AFV40D-S421202, AFV40D-421202/ATDOC, AFV40D-S421202/CH, AFV40D-421202/CE

AFV40D-S421402, AFV40D-421402/ATDOC, AFV40D-S421402/CH, AFV40D-421402/CE

AFV40D-S422102, AFV40D-422102/ATDOC, AFV40D-S422102/CH, AFV40D-422102/CE

AFV40D-S422202, AFV40D-422202/ATDOC, AFV40D-S422202/CH, AFV40D-422202/CE

AFV40D-S422402, AFV40D-422402/ATDOC, AFV40D-S422402/CH, AFV40D-422402/CE

AFV40D-S441102, AFV40D-441102/ATDOC, AFV40D-S441102/CH, AFV40D-441102/CE

AFV40D-S441202, AFV40D-441202/ATDOC, AFV40D-S441202/CH, AFV40D-441202/CE

AFV40D-S441402, AFV40D-441402/ATDOC, AFV40D-S441402/CH, AFV40D-441402/CE

AFV40D-S442102, AFV40D-442102/ATDOC, AFV40D-S442102/CH, AFV40D-442102/CE

AFV40D-S442202, AFV40D-442202/ATDOC, AFV40D-S442202/CH, AFV40D-442202/CE

AFV40D-S442402, AFV40D-442402/ATDOC, AFV40D-S442402/CH, AFV40D-442402/CE