  • ABB valve positioner V18345 Electro-Pneumatic Positioner TZIDC

ABB valve positioner V18345 Electro-Pneumatic Positioner TZIDC

2015-06-24 16:18:53

Description:

The TZIDC is an electronically configurable positioner with communication capabilities designed for mounting to pneumatic linear or rotary actuators. It features a small and compact design, a modular construction, and an excellent cost-performance ratio. Fully automatic determination of the control parameters and adaptation to the final control element yield considerable time savings and an optimal control behavior.……

New Products

G.M. International D5015SK Intrinsically Safe Isolators - Analog Input

G.M. International D5015SK Intrinsically Safe Isolators - Analog Input. I.S. SIL2 2/4-Wire HART® Transmitter Power Supply.

G.M. International D5015SK Intrinsically Safe Isolators - Analog Input

G.M. International D5015SK Intrinsically Safe Isolators - Analog Input. I.S. SIL2 2/4-Wire HART® Transmitter Power Supply.

G.M. International D5015SK Intrinsically Safe Isolators - Analog Input

G.M. International D5015SK Intrinsically Safe Isolators - Analog Input. I.S. SIL2 2/4-Wire HART® Transmitter Power Supply.

G.M. International D5016DK Intrinsically Safe Isolators - Analog Input

G.M. International D5016DK Intrinsically Safe Isolators - Analog Input. I.S. SIL3 2-Wire Active HART® Tx Current Repeater.

Assortments

Description

Quick Details

Standard or Nonstandard:

Standard

Structure:

Ball

Pressure:

High Pressure

Power:

Pneumatic

Material:

Brass

Temperature of Media:

High Temperature

Media:

Water

Place of Origin:

Germany

Model Number:

TZIDC

Brand Name:

ABB





Packaging & Delivery

Packaging Details:with standard carton
Delivery Detail:4 weeks

Specifications

long lifetime control Positioner for model TZIDC V18345 series 
HART protocol 
Low operating cost 
For 4 20 mA two-wire

long lifetime control Positioner for model TZIDC V18345 series 

 

Specifications
1 Input
Setpoint signal (two-wire technology)

  • Nominal range 4 ... 20 mA

  • Split range configuration between 20 ... 100 % of the nominal range

  • Max. 50 mA

  • Min. 3.6 mA

  • Starting at 3.8 mA

  • Load voltage at 20 mA 9.7 V

  • Impedance at 20 mA 485 Ω

Digital input

  • Control voltage 0 ... 5 V DC

  • logical switching state "0"

  • 11 ... 30 V DC

  • logical switching state "1"

  • Current max. 4 mA

2. Output
Compressed air output

  • Range 0 ... 6 bar (0 ... 90 psi)

  • Air capacity 5.0 kg/h = 3.9 Nm3/h = 2.3 sfcm

  • at 1.4 bar (20 psi) supply pressure

  • 13 kg/h = 10 Nm3/h = 6.0 sfcm

  • at 6 bar (90 psi) supply pressure

  • Output function For single or double-acting

  • actuators, air is vented from

  • actuator or actuator is blocked in

  • case of (electrical) power failure

  • Shut-off values End position 0 % = 0 ... 45 %

  • End position 100 % = 55 ... 100 %

Digital output (control circuit to DIN 19234 / NAMUR)

  • Supply voltage 5 ... 11 V DC

  • Current > 0.35 mA ... < 1.2 mA Switching state logical "0"

  • Current > 2.1 mA Switching state logical "1"

  • Effective direction (configurable) normally logical "0" or logical "1"

3 Travel

  • Rotation angle

  • Used range 25 ... 120° (rotary actuators, optional 270°) 25 ... 60 ° (linear actuators)

  • Travel limit Min. and max. limits, freely configurable between 0 ... 100 % of total travel (min. range > 20 %)

  • Travel time prolongation Range of 0 ... 200 s, separately for each direction

  • Dead band time limit Setting range 0 ... 200 s (monitoring parameter for control until the deviation reaches the dead band)