Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Schneider CMA / CMV / iCMA / iCMV - Panel & DIN-rail mounted modular selector switches

Schneider CMA / CMV / iCMA / iCMV - Panel & DIN-rail mounted modular selector switches

2015-06-18 17:15:31

Description:

CMA / CMV / iCMA / iCMV - Panel & DIN-rail mounted modular selector switches……

New Products

OMRON 3G3MX2-AB022-V2 inverter drive

OMRON 3G3MX2-AB022-V2 MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz

OMRON 3G3MX2-AB015-V2 inverter drive

OMRON 3G3MX2-AB015-V2 MX2-EV2 inverter drive, 1.5/2.2 kW (ND/LD), 8.0/9.6 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz.

OMRON 3G3MX2-AB007-V2 inverter drive

OMRON 3G3MX2-AB007-V2 MX2-EV2 inverter drive, 0.75/1.1 kW (ND/LD), 5.0/6.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz

OMRON 3G3MX2-AB004-V2 inverter drive

OMRON 3G3MX2-AB004-V2 MX2-EV2 inverter drive, 0.4/0.55 kW (ND/LD), 3.0/3.5 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz

Assortments

Description

CMA / CMV / iCMA / iCMV

Gallery


CMA / CMV / iCMA / iCMV - Panel & DIN-rail mounted modular selector switches

PowerLogic and Acti 9 modular selector switches for ammeters and voltmeters



PowerLogic CMA and CMV panel mounted (48x48) selector switches 

Acti 9 iCMA and iCMV DIN-rail mounted selector switches

The 48 x 48 selector switches are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles:

  • CMA - The ammeter selector switch uses a single ammeter (by means of current transformers) for successive measurement of the currents of a three-phase circuit.

  • CMV - The voltmeter selector switch uses a single voltmeter for successive measurement of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.


The DIN rail switches have jumper terminal connection with captive screws for cables:

  • iCMA - This 4-position ammeter selector switch uses a single ammeter (using current transformers) for successive measurement of the currents of a three-phase circuit.

  • iCMV - This 7-position voltmeter selector switch uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.

Benefits

It allows space savings in an electrical switchboard.

Applications

Panel instrumentation


Documents & Downloads