E+H CYK10-A051 Digital measuring cable, Endress+Hauser CYK10 Memosens
2021-05-12 15:20:12
Description:
E+H CYK10-A051 Digital measuring cable, Endress+Hauser CYK10 Memosens. Memosens data cable for all sensors with Memosens plug-in head. Inductive, digital transmission of measurement signals and energy.……
New Products
HCD2-FBPS-1.500 Fieldbus Power Supply - Pepperl+Fuchs
HCD2-FBPS-1.500 Fieldbus Power Supply, module for fieldbus power hub. This Power Supply Module is a system component for the FieldConnex®Power Hub and can be plugged into the motherboard.
HiC2025 SMART Transmitter Power Supply - Pepperl+Fuchs
Pepperl+Fuchs HiC2025 is a SMART transmitter power supply designed for analog input, boasting a Safety Integrity Level (SIL) of 2 and a Systematic Capability (SC) of 3.
HiC2031 SMART Current Driver - Pepperl+Fuchs
Pepperl+Fuchs HiC2031 is a SMART Current Driver featuring analog output. This isolated barrier is used for intrinsic safety applications.
OMRON 3G3MX2-AB022-V2 inverter drive
OMRON 3G3MX2-AB022-V2 MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz
Assortments
Description
E+H CYK10-A051 Digital measuring cable, Endress+Hauser CYK10 Memosens. Memosens data cable for all sensors with Memosens plug-in head. Inductive, digital transmission of measurement signals and energy.
Endress+Hauser CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
Device details
Product name: Meas. cable CYK10 Memosens
Order code: CYK10-A051
Characteristic | Value | Description |
Approval: | A | Non-hazardous area |
Cable Length: | 05 | 5m |
Cable Connection: | 1 | Wire terminals |
Endress+Hauser CYK10 Memosens Features:
● Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.
● Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.
● More flexibility in plant planning and installation: Cable length up to 100 m is possible.
● Approved for hazardous area use.
Endress+Hauser CYK10 Memosens more model:
CYK10-A101
CYK10-A031
CYK10-G881
CYK10-A151
CYK10-A881
...