Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
2019-06-04 15:27:16
Description:
± 0.5°C (± 0.9 °F) for T/C only Include influence of the ambient temperature.……
Notice:
New Products
Emerson TREXCHPKL9S1 AMS Trex device communicator
Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3S AMS Trex device communicator
Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3 AMS Trex device communicator
Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP1S AMS Trex device communicator
Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
Specifications of Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
Accuracy
HART communication type: A/D accuracy/span + D/A accuracy (See Table 7.1.)
Fieldbus communication type: A/D accuracy (See Table 7.1.)
Cold Junction Compensation Accuracy
± 0.5°C (± 0.9 °F) for T/C only Include influence of the ambient temperature.
Ambient Temperature Effect (per 10°C change)
±0.1% or ±(Temperature coefficient/span), whichever is greater. (See Table 7.2.)
Stability
RTD: ±0.1% of reading or ±0.1°C per 2 years, whichever is greater at 23±2°C.
T/C: ±0.1% of reading or ±0.1°C per year, whichever is greater at 23±2°C.
Function block of Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
Function block | Execution time (ms) |
AI | 30 |
DI | 30 |
SC | 30 |
IS | 30 |
AR | 30 |
PID | 45 |
Similar model codes of Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1 for your reference :
YTA610-JA1A4DD/A/FU1, YTA610-JA2A2NN/FU1, YTA610-JA1A4DB, YTA610-JA1A2DD, YTA610-JA1A4DN/KU2/A/C1, YTA610-JA1A4NN/SU2/X2/C3/N4, YTA610-FA2A4DN/KU25, YTA610-JA1A4DN/KU2, YTA610-JA1A4DN/KU2/A, YTA610-JA1A2DN/KU2, YTA610-JA1C0NK
If you have any question, please do not hesitate to contact with me online
Contact details :
Shirley Sun
Sales Engineer
HONGKONG XIEYUAN TECH CO., LIMITED
Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China
M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85802699 | F : +86-27-85309780
Email : Shirley@whxyauto.com Skype : 169649423@qq.com
Web : www.hkxytech.com