Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
2019-06-04 15:27:16
Description:
± 0.5°C (± 0.9 °F) for T/C only Include influence of the ambient temperature.……
New Products
OMRON 3G3MX2-AB022-V2 inverter drive
OMRON 3G3MX2-AB022-V2 MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz
OMRON 3G3MX2-AB015-V2 inverter drive
OMRON 3G3MX2-AB015-V2 MX2-EV2 inverter drive, 1.5/2.2 kW (ND/LD), 8.0/9.6 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz.
OMRON 3G3MX2-AB007-V2 inverter drive
OMRON 3G3MX2-AB007-V2 MX2-EV2 inverter drive, 0.75/1.1 kW (ND/LD), 5.0/6.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz
OMRON 3G3MX2-AB004-V2 inverter drive
OMRON 3G3MX2-AB004-V2 MX2-EV2 inverter drive, 0.4/0.55 kW (ND/LD), 3.0/3.5 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz
Assortments
▶ Pressure Transmitter EJA
▶ Pressure Transmitters EJA-E
▶ Pressue Transmitter EJX
▶ Safety Instrumented System (SIS)
▶ Valve Positioners & Converters
▶ Field Mount Indicators
▶ Temperature Transmitters
▶ Magnetic Flowmeters
▶ Vortex Flowmeter
▶ Ultrasonic Flowmeters
▶ Coriolis Mass Flowmeters - ROTAMASS 3-Series
▶ Variable Area Flowmeters – Rotameters
▶ Device Smart Communicators
▶ PORTABLE AND HANDHELD INSTRUMENTS
▶ Distributed Control System (DCS)
▶ Process Analyzers
▶ Paperless Recorders
▶ Strip Chart Recorders
▶ Data Acquisition Equipment
▶ UT Series Temperature Controllers
▶ UP Series Program Controllers
▶ UM Series Digital Indicators with Alarms
▶ UT100 Series Temperature Controllers
▶ UD Series Manual Setters
▶ Limit Controllers
▶ YS Series Single-loop Controllers
Description
Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
Specifications of Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
Accuracy
HART communication type: A/D accuracy/span + D/A accuracy (See Table 7.1.)
Fieldbus communication type: A/D accuracy (See Table 7.1.)
Cold Junction Compensation Accuracy
± 0.5°C (± 0.9 °F) for T/C only Include influence of the ambient temperature.
Ambient Temperature Effect (per 10°C change)
±0.1% or ±(Temperature coefficient/span), whichever is greater. (See Table 7.2.)
Stability
RTD: ±0.1% of reading or ±0.1°C per 2 years, whichever is greater at 23±2°C.
T/C: ±0.1% of reading or ±0.1°C per year, whichever is greater at 23±2°C.
Function block of Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1
Function block | Execution time (ms) |
AI | 30 |
DI | 30 |
SC | 30 |
IS | 30 |
AR | 30 |
PID | 45 |
Similar model codes of Yokogawa YTA610-JA1A4DD/A/FU1 Temperature Transmitter YTA610-JA1A4DD/A/FU1 for your reference :
YTA610-JA1A4DD/A/FU1, YTA610-JA2A2NN/FU1, YTA610-JA1A4DB, YTA610-JA1A2DD, YTA610-JA1A4DN/KU2/A/C1, YTA610-JA1A4NN/SU2/X2/C3/N4, YTA610-FA2A4DN/KU25, YTA610-JA1A4DN/KU2, YTA610-JA1A4DN/KU2/A, YTA610-JA1A2DN/KU2, YTA610-JA1C0NK
If you have any question, please do not hesitate to contact with me online
Contact details :
Shirley Sun
Sales Engineer
HONGKONG XIEYUAN TECH CO., LIMITED
Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China
M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85802699 | F : +86-27-85309780
Email : Shirley@whxyauto.com Skype : 169649423@qq.com
Web : www.hkxytech.com