Honeywell Analytics Manning AirAlert 96d Toxic and Combustible Gas Detector Gas Detection Controllers
2019-03-08 16:19:53
Description:
Multi-channel gas monitoring system acts as the nerve center of a modular gas detection network, providing continuous……
New Products
HCD2-FBPS-1.500 Fieldbus Power Supply - Pepperl+Fuchs
HCD2-FBPS-1.500 Fieldbus Power Supply, module for fieldbus power hub. This Power Supply Module is a system component for the FieldConnex®Power Hub and can be plugged into the motherboard.
HiC2025 SMART Transmitter Power Supply - Pepperl+Fuchs
Pepperl+Fuchs HiC2025 is a SMART transmitter power supply designed for analog input, boasting a Safety Integrity Level (SIL) of 2 and a Systematic Capability (SC) of 3.
HiC2031 SMART Current Driver - Pepperl+Fuchs
Pepperl+Fuchs HiC2031 is a SMART Current Driver featuring analog output. This isolated barrier is used for intrinsic safety applications.
OMRON 3G3MX2-AB022-V2 inverter drive
OMRON 3G3MX2-AB022-V2 MX2-EV2 inverter drive, 2.2/3.0 kW (ND/LD), 11.0/12.0 A (ND/LD), 200 VAC, 1~ input, sensorless vector, max. output freq. 590Hz
Assortments
Description
Honeywell Analytics Manning AirAlert 96d Toxic and Combustible Gas Detector Gas Detection Controllers
General Specification | |
Use | Multi-channel gas monitoring system acts as the nerve center of a modular gas detection network, providing continuous monitoring of up to 96 connected units on three distinct channels. |
Common Operation | |
Display | Graphic 122 x 82 alphanumeric dot matrix backlit |
Push Button Controls | Seven user-friendly pushbuttons easily performs operations from minor fine tuning to reconfiguration of entire network |
Electrical Power | 24 VDC, 500 mA (18-36 VDC) |
Communication Addressable | RS-485 Modbus protocol |
Power Supply | External M-600400 24 VDC, 6.5 amps, enclosure complies with Nema 4 requirements |
Environmental | |
Operating Altitude | Up to 3,000 m (9843 ft.) |
Operating Environment | Ordinary location |
Operational Humidity | 0-95% RH (non-condensing) |
Temperature | -20°C to +50°C (-4°F to +122°F) |
Common Module | |
Communication | RS-485: for communication cable, use 24 AWG twisted pair, shielded (Belden #9841 or equal), cable runs up to 2,000 ft. For power cable use 14 AWG (Belden #5100UE or equal), cable runs up to 1,000 feet.(Belden #5100UE or equal), cable runs up to 1,000 feet |
Network Capacity | Up to 96 sensors, 32 per channel Channel 1, 2, and 3 |
Visual Indicators | Power On Green LED Warn Red LED (blinks upon an event) Alarm Red LED High Alarm Red LED Fault Yellow LED Tx Amber LED (blinks when used) Rx Green LED (blinks when used) |
Outputs | |
Relays | 4 DPDT relays 5A, 30 Vdc or 250 VAC/30 VDC Field selectable: energized/de-energized Red LED for each relay for alarm indication: One common warn gas alarm One common alarm gas alarm One common high gas alarm One common fault alarm |
Communication | BACnet output only |
Time Delays | 0, 30, and 45 seconds, and 1 to 99 minutes before and after alarm |
Enclosure | NEMA 4x, cast aluminum #A356.0T6, EMI/RFI protected |
Over-voltage Category | II |
Dimensions | 24.1 x 35.6 x 8.9 cm (9.50” x 14” x 3.5”) |
Weight | 5.2 kg (11.4 lbs) |
If you have any question, please do not hesitate to contact with me online
Contact details :
Shirley Sun
Sales Engineer
HONGKONG XIEYUAN TECH CO., LIMITED
Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China
M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780 | F : +86-27-85309780
Email : Shirley@whxyauto.com Skype : 169649423@qq.com
Web : www.hkxytech.com