
Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters
2019-01-09 17:21:39
Description:
3-wire, 4-20mA, transmitter with optional Modbus for use with remotely mounted flammable gas sensors 705 and 705HT……
New Products
Allen-Bradley 20F11NC104JA0NNNNN PowerFlex 753 AC Drive
Allen-Bradley 20F11NC104JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals
Allen-Bradley 20F11NC060JA0NNNNN PowerFlex 753 AC Drive
Allen-Bradley 20F11NC060JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals
Allen-Bradley 20F11NC043JA0NNNNN PowerFlex 753 AC Drive
Allen-Bradley 20F11NC043JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals
Allen-Bradley 20F11NC037JA0NNNNN PowerFlex 753 AC Drive
Allen-Bradley 20F11NC037JA0NNNNN PowerFlex 753 AC Drive, with Embedded I/O, Standard Protection, Forced Air, AC Input with DC Terminals
Assortments
Description
Honeywell Analytics Sensepoint XCD RFD Remote Flammable Gas Monitor Explosion-Proof Transmitters Industrial Gas Systems
Use | 3-wire, 4-20mA, transmitter with optional Modbus for use with remotely mounted flammable gas sensors 705 and 705HT |
Electrical | |
Input Voltage Range | 16 to 32VDC (24VDC nominal) |
Max Power Consumption | Max 5 Watts. at 24Vdc (see section 2 regarding maximum in rush current) |
Current Output | 4-20mA (Source or Sink) ≥0.0<1.0 mA: Fault 4.0 mA to 20.0 mA: Inhibit (during configuration/user settings) 22.0 mA: Maximum over range |
Terminals | 15 x screw terminals suitable for wire diameter 0.5mm2 to 2.5mm 2 (20AWG to 13AWG) |
Relays | 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energized (programmable) |
Communication | RS485, Modbus RTU |
Construction | |
Material | Epoxy painted aluminium alloy or 316 Stainless Steel |
Weight (approx) | Aluminium Alloy LM25: 4.4lbs 316 Stainless Steel: 11lbs |
Mounting | Pole or wall mounting |
Cable Entries | 2 x ¾” NPT |
Sensor Entries | ¾” NPT |
Environmental | |
IP Rating | IP66 in accordance with EN60529:1992, NEMA 4X (Tested by third party laboratory) |
Operating Temperature | -40ºF to +149ºF (-40ºC to +65ºC) |
Operating Humidity | Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing) |
Operating Pressure | 90-110kPa |
Storage Conditions | -13°F to +149°F (-25°C to +65°C) |
Certification | |
US | cCSAus approved for Class I, Division 1, Groups B, C & D Hazardous Locations. Performance approved to the following standards; ANSI/ISA-12.13.01 |
Canada | cCSAus approved for Class I, Division 1, Groups B, C & D Hazardous Locations. Performance approved to the following standards; C22.2 No. 152-M1984 |
Performance | C22.2-152, ANSI/ISA 121301 |
If you have any question, please do not hesitate to contact with me online
Contact details :
Shirley Sun
Sales Engineer
HONGKONG XIEYUAN TECH CO., LIMITED
Add : 7-A16, Caishen Commercial Plaza, Hankou Railway Station, Wuhan, China
M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780 | F : +86-27-85309780
Email : Shirley@whxyauto.com Skype : 169649423@qq.com
Web : www.hkxytech.com