RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 1999PPM G01-0103-000
2018-08-30 23:53:05
Description:
RAE SYSTEMS by Honeywell ToxiRAE 3 Full-featured, single-gas monitor for CO and H2S……
Notice:
New Products
Emerson TREXCHPKL9S1 AMS Trex device communicator
Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3S AMS Trex device communicator
Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3 AMS Trex device communicator
Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP1S AMS Trex device communicator
Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Assortments
Description
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 1999PPM G01-0103-000
RAE SYSTEMS by Honeywell ToxiRAE 3 Full-featured, single-gas monitor for CO and H2S
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Monitor G01-0102-000
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor H2S Detector G01-0102-010
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Detector G01-0101-000
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor G01-0101-010
RAE SYSTEMS by Honeywell ToxiRAE 3 Portable Single-Gas Monitor CO Monitor 0 to 500 PPM G01-0101-100
This portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S). The ToxiRAE 3’s high-performance, three-electrode sensor delivers the fastest possible response time. When used with the AutoRAE Lite bump test and calibration station, it provides a low total cost of ownership (TCO) to organizations that are looking to protect workers and deliver worksite CO and H2S personal detection compliance. With its water and dust-resistant housing, and three-alarm capability, it’s a valuable tool for ensuring workers are aware of the presence of CO or H2S.
Key Features:
Fully featured single-gas monitor
0.1ppm resolution on Hydrogen Sulfide (H2S) sensor
Carbon monoxide (CO) sensor
Can record STEL, TWA, high and low alarms
High-performance sensor for fastest possible response time
Compatible with AutoRAE Lite bump test and calibration station
Large, easy-to-read display
Lightweight, easy to wear and use
Logs up to 10 events
Water- and dust-resistant
Audible, visual, and vibration alarm
Applications:
Emergency Response
Exploration
Fracking
Hazmat Response
Plant Shutdown & Turn-Around
Residential Calls
Worker Exposure
Specifications
Detector Specifications
Size 3.4" x 2.2" x 0.8" (8.6 cm x 5.5 cm x 2.0 cm)
Weight 3.5 oz (99.4 g)
Battery User-replaceable 2/3 AA high-capacity lithium
Alarms:
1) 95 dB typical (at 30 cm) buzzer and flashing red LED to indicate exceeded preset limits
2) High: Displays “High” and emits 3 beeps and flashes per second
3) Low: Displays “Low” and emits 2 beeps and flashes per second
4) STEL: Displays “STEL” and emits 1 beep and flash per second
5) TWA: Displays “TWA” and emits 1 beep and flash per second
6) Vibration alarm
7) 6-LED visible alarm
Data logging 10 events
Response time T90 < 12 seconds
IP Rating IP-67
EMI/RFI:
Highly resistant to EMI/RFI.
Compliant with EMC directive 2004/108/ECCertification
cCSAus: C1D1, Groups A, B, C, D, T4
ATEX: II 1G Ex ia IIC T4 Ga
IECEX: Ex ia IIC T4 Ga
Operating Temperature:
Continuous: -4° to 140° F (-20° to +60° C)
Intermittent: -22° to 140° F (-30° to +60° C)Humidity 0 to 95% relative humidity (non-condensing)
Warranty 2 years, including sensor and battery if used within specs
Calibration Two-point calibration for zero and span
Sensor Specifications | ||
Gas | Gas Range (ppm) | Resolution (ppm) |
H2S | 0 to 100 | 0.1 |
CO | 0 to 500 | 1 |
CO | 0 to 1999 | 1 |
ToxiRAE 3 Ordering Options
Pack of 1:
ToxiRAE 3 with specified sensor:
2/3 AA lithium battery
One mini-CD with instruction manual and training materials
Alligator clip
Calibration adapter
Pack of 10:
10 ToxiRAE 3 monitors with specified sensor
2mini-CDswith instructionmanual and trainingmaterials
2 calibration adapters
10 alligator clips
Pack of 100:
10 packs of 10
Accessories (optional)
AutoRAE Lite Automatic Test and Calibration Station
Ordering Information | |||
Monitor | Pack of 1 | Pack of 10 | Pack of 100 |
H2S | G01-0102-000 | G01-0102-010 | G01-0102-100 |
CO Low range | G01-0101-000 | G01-0101-010 | G01-0101-100 |
CO High range | G01-0103-000 | G01-0103-010 | G01-0103-100 |
AutoRAE Lite | |||
Bump Test and Calibration Station | T01-0100-000 |
Ava Wong
Sales Manager
HONGKONG XIEYUAN TECH CO., LIMITED
M: +86-15602323637 (WhatsApp & Wechat) | T: +86-27-85581877 | F: +86-27-85309780
Email: ava.wong@hkxytech.com Skype: ava.huang4
Web: www.gasanalytics.net