Pepperl Fuchs KFA6-SOT2-Ex2 Explosion Protection Products Intrinsic Safety Barriers Isolated Barriers Switch Amplifiers
2018-07-31 17:17:26
Description:
2-channel isolated barrier 230 V AC supply Dry contact or NAMUR inputs Passive transistor output, non-polarized ……
Notice:
New Products
Emerson TREXCHPKL9S1 AMS Trex device communicator
Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3S AMS Trex device communicator
Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3 AMS Trex device communicator
Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP1S AMS Trex device communicator
Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Assortments
Description
Pepperl Fuchs KFA6-SOT2-Ex2 Explosion Protection Products Intrinsic Safety Barriers Isolated Barriers K-System Switch Amplifiers
2-channel isolated barrier
230 V AC supply
Dry contact or NAMUR inputs
Passive transistor output, non-polarized
Line fault detection (LFD)
Reversible mode of operation
Up to SIL 2 acc. to IEC 61508
Datasheet excerpt: Technical data of KFA6-SOT2-Ex2
General specifications | |
Signal type | Digital Input |
Functional safety related parameters | |
Safety Integrity Level (SIL) | SIL 2 |
Supply | |
Connection | terminals 14, 15 |
Rated voltage | 207 ... 253 V AC, 45 ... 65 Hz |
Power dissipation | 1 W |
Power consumption | max. 1.5 W |
Input | |
Connection side | field side |
Connection | terminals 1+, 2+, 3-; 4+, 5+, 6- |
Rated values | acc. to EN 60947-5-6 (NAMUR), see system description for electrical data |
Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA |
Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA |
Line fault detection | breakage I ≤ 0.1 mA , short-circuit I > 6 mA |
Similar model codes for your reference :
KFA6-DU-Ex1.D
KFA6-DWB-Ex1.D
KFA6-ER-1.5
KFA6-ER-1.6
KFA6-ER-1.W.LB
KFA6-ER-2.W.LB
KFA6-ER-Ex1.W.LB
KFA6-SOT2-Ex2
KFA6-SR-2.3L
KFA6-SR-2.3L.FA
KFA6-SR2-Ex1.W
KFA6-SR2-Ex1.W.LB
KFA6-SR2-Ex2.W
KFA6-SR2-Ex2.W.IR
KFA6-STR-1.24.500
KFA6-STR-1.24.4
If you have any question, please do not hesitate to contact with me online
Contact details :
Shirley Sun
Sales Engineer
HONGKONG XIEYUAN TECH CO., LIMITED
Add : 7-A16, Caishen Commercial Plaza, Hangkou Railway Station, Wuhan, China
M : +86-15172506760 (WhatsApp & Wechat) | T : +86-27-85309780 | F : +86-27-85309780
Email : Shirley@whxyauto.com Skype : 169649423@qq.com
Web : www.hkxytech.com