Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Honeywell XNX-AMAV-NHIV1 XNX Gas Detector XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)

Honeywell XNX-AMAV-NHIV1 XNX Gas Detector XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)

2018-04-01 19:32:22

Description:

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Honeywell XNX-AMAV-NHIV1 XNX Gas Detector XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)



XNX UNIVERSAL TRANSMITTER


XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies.

It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.


XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART? terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.


1. XNX Universal Transmitter- Flammable Standard Temperature with MPD sensor

1.1. INSTRUMENT

XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL

XNX Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor 0-100%LEL

XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

XNX Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL

XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)

XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)

XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V

XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V

XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V)

XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V

1.2. SPARE MPD SENSORS

1.3. SPARE MPD REPLACEABLE CARTRIDGES


2. XNX Universal Transmitter- for use with Sensepoint HT or 705 HT Flammable Sensor

3. XNX Universal Transmitter- for use with XNX Toxic & Oxygen Sensors

4. XNX Universal Transmitter- for use with Optima Plus Or Searchline Excel Detectors

5. Searchline Excel kits with XNX Transmitters

6. XNX Universal Transmitter Accessories and Spare Parts

XNX Aluminium   Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL
XNX-AMAV-NNCB1   XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25   entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL
XNX-AMAV-NHCB1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD   catalytic sensor 0-100%LEL
XNX-AMAV-RNCB1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD   catalytic sensor 0-100%LEL
XNX-AMAV-RHCB1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD catalytic sensor 0-100%LEL
XNX-AMAV-MNCB1   XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4   x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL
XNX-AMAV-MHCB1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD catalytic sensor 0-100%LEL
XNX-AMAV-FNCB1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD   catalytic sensor 0-100%LEL
XNX-AMAV-FHCB1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD catalytic sensor 0-100%LEL
XNX   Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor   0-100%LEL
XNX-AMSV-NNCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, including MPD catalytic sensor   0-100%LEL.
XNX-AMSV-NHCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with local HART® interface port,   including MPD catalytic sensor 0-100%LEL.
XNX-AMSV-RNCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with alarm and fault relay outputs,   including MPD catalytic sensor 0-100%LEL.
XNX-AMSV-RHCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with alarm and fault relay outputs and   local HART® interface port, including MPD catalytic sensor 0-100%LEL.
XNX-AMSV-MNCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with Modbus® output, including MPD   catalytic sensor 0-100%LEL.
XNX-AMSV-MHCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with Modbus® output and local HART®   interface port, including MPD catalytic sensor 0-100%LEL.
XNX-AMSV-FNCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD catalytic sensor 0-100%LEL.
XNX-AMSV-FHCB1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD catalytic sensor   0-100%LEL.
XNX   Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane)   Sensor 0-100%LEL
XNX-AMAV-NNIF1   XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25   entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor   0-100%LEL
XNX-AMAV-NHIF1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR   hydrocarbon (Propane) sensor 0-100%LEL
XNX-AMAV-RNIF1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR   hydrocarbon (Propane) sensor 0-100%LEL
XNX-AMAV-RHIF1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX-AMAV-MNIF1   XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4   x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane)   sensor 0-100%LEL
XNX-AMAV-MHIF1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX-AMAV-FNIF1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR   hydrocarbon (Propane) sensor 0-100%LEL
XNX-AMAV-FHIF1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX   Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor   0-100%LEL
XNX-AMSV-NNIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, including MPD IR flammable (propane)   sensor 0-100%LEL.
XNX-AMSV-NHIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with local HART® interface port,   including MPD IR flammable sensor 0-100%LEL.
XNX-AMSV-RNIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with alarm and fault relay outputs,   including MPD IR flammable sensor 0-100%LEL.
XNX-AMSV-RHIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with alarm and fault relay outputs and   local HART® interface port, including MPD IR flammable sensor 0-100%LEL.
XNX-AMSV-MNIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with Modbus® output, including MPD IR   flammable sensor 0-100%LEL.
XNX-AMSV-MHIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with Modbus® output and local HART®   interface port, including MPD IR flammable sensor 0-100%LEL.
XNX-AMSV-FNIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD IR flammable sensor 0-100%LEL.
XNX-AMSV-FHIF1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD IR flammable sensor   0-100%LEL.
XNX   Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor   0-100%LEL (0-5%V/V).
XNX-AMAV-NNIV1   XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25   entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor   0-100%LEL (0-5%v/v)
XNX-AMAV-NHIV1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR   hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-AMAV-RNIV1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR   hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-AMAV-RHIV1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-AMAV-MNIV1   XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4   x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane)   sensor 0-100%LEL (0-5%v/v)
XNX-AMAV-MHIV1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-AMAV-FNIV1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR   hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-AMAV-FHIV1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX   Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor   0-100%LEL (0-5%V/V).
XNX-AMSV-NNIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, including MPD IR methane sensor   0-100%LEL (0-5%V/V).
XNX-AMSV-NHIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional local HART® interface   port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-AMSV-RNIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional alarm and fault relay   outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-AMSV-RHIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional alarm and fault relay   outputs and local HART ® interface port, including MPD IR methane sensor   0-100%LEL (0-5%V/V).
XNX-AMSV-MNIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Modbus® output, including   MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-AMSV-MHIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Modbus® output and local   HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-AMSV-FNIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD IR methane sensor 0-5%V/V.
XNX-AMSV-FHIV1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD IR methane sensor   0-5%V/V.
XNX Aluminium Transmitter   ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V.
XNX-AMAV-NNIC1   XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25   entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v
XNX-AMAV-NHIC1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2   sensor 0-5%v/v
XNX-AMAV-RNIC1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2   sensor 0-5%v/v
XNX-AMAV-RHIC1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR CO2 sensor 0-5%v/v
XNX-AMAV-MNIC1   XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4   x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v
XNX-AMAV-MHIC1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR CO2 sensor 0-5%v/v
XNX-AMAV-FNIC1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output,   ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2   sensor 0-5%v/v
XNX-AMAV-FHIC1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium,   includes MPD IR CO2 sensor 0-5%v/v.
XNX Stainless Steel Transmitter ATEX/IEC   with MPD Infrared CO2 Sensor 0-5%V/V.
XNX-AMSV-NNIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V.
XNX-AMSV-NHIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with local HART® interface port,   including MPD IR CO2 sensor 0-5%V/V.
XNX-AMSV-RNIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with alarm and fault relay outputs,   including MPD IR CO2 sensor 0-5%V/V.
XNX-AMSV-RHIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with alarm and fault relay outputs and   local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.
XNX-AMSV-MNIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with Modbus® output, including MPD IR   CO2 sensor 0-5%V/V.
XNX-AMSV-MHIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with Modbus® output and local HART®   interface port, including MPD IR CO2 sensor 0-5%V/V.
XNX-AMSV-FNIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD IR CO2 sensor 0-5%V/V.
XNX-AMSV-FHIC1   XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.
XNX Aluminium Transmitter UL/CSA with MPD   Catalytic Sensor 0-100%LEL
XNX-UTAV-NNCB1   XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,   painted Aluminium, includes MPD catalytic sensor 0-100%LEL
XNX-UTAV-NHCB1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic   sensor 0-100%LEL
XNX-UTAV-RNCB1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor   0-100%LEL
XNX-UTAV-RHCB1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD catalytic sensor 0-100%LEL
XNX-UTAV-MNCB1   XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x   3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor   0-100%LEL
XNX-UTAV-MHCB1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes   MPD catalytic sensor 0-100%LEL
XNX-UTAV-FNCB1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor   0-100%LEL
XNX-UTAV-FHCB1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD catalytic sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA   with MPD Catalytic Sensor 0-100%LEL
XNX-UTSV-NNCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, including MPD catalytic sensor   0-100%LEL.
XNX-UTSV-NHCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with local HART® interface port,   including MPD catalytic sensor 0-100%LEL.
XNX-UTSV-RNCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with alarm and fault relay outputs,   including MPD catalytic sensor 0-100%LEL.
XNX-UTSV-RHCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with alarm and fault relay outputs and   local HART® interface port, including MPD catalytic sensor 0-100%LEL.
XNX-UTSV-MNCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with Modbus® output, including MPD   catalytic sensor 0-100%LEL.
XNX-UTSV-MHCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with Modbus® output and local HART®   interface port, including MPD catalytic sensor 0-100%LEL.
XNX-UTSV-FNCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD catalytic sensor 0-100%LEL.
XNX-UTSV-FHCB1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD catalytic sensor   0-100%LEL.
XNX Aluminium Transmitter UL/CSA with MPD   Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
XNX-UTAV-NNIF1   XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,   painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX-UTAV-NHIF1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR   hydrocarbon (Propane) sensor 0-100%LEL
XNX-UTAV-RNIF1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon   (Propane) sensor 0-100%LEL
XNX-UTAV-RHIF1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX-UTAV-MNIF1   XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x   3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon   (Propane) sensor 0-100%LEL
XNX-UTAV-MHIF1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes   MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX-UTAV-FNIF1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon   (Propane) sensor 0-100%LEL
XNX-UTAV-FHIF1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL
XNX Stainless Steel Transmitter UL/CSA   with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL
XNX-UTSV-NNIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, including MPD IR flammable sensor   0-100%LEL.
XNX-UTSV-NHIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with local HART® interface port,   including MPD IR flammable sensor 0-100%LEL.
XNX-UTSV-RNIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with alarm and fault relay outputs,   including MPD IR flammable sensor 0-100%LEL.
XNX-UTSV-RHIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with alarm and fault relay outputs and   local HART® interface port, including MPD IR flammable sensor 0-100%LEL.
XNX-UTSV-MNIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with Modbus® output, including MPD IR   flammable sensor 0-100%LEL.
XNX-UTSV-MHIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with Modbus® output and local HART®   interface port, including MPD IR flammable sensor 0-100%LEL.
XNX-UTSV-FNIF1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD IR flammable sensor 0-100%LEL.
XNX   -UTSV-FHIF1 XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x   3/4"NPT entries, painted 316 stainless steel, with optional Foundation   Fieldbus™ output and local HART® interface port, including MPD IR flammable   sensor 0-100%LEL.
XNX   Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL   (0-5%V/V).
XNX-UTAV-NNIV1   XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,   painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL   (0-5%v/v)
XNX-UTAV-NHIV1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR   hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-UTAV-RNIV1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon   (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-UTAV-RHIV1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-UTAV-MNIV1   XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x   3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon   (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-UTAV-MHIV1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes   MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-UTAV-FNIV1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon   (Methane) sensor 0-100%LEL (0-5%v/v)
XNX-UTAV-FHIV1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)
XNX Stainless Steel Transmitter UL/CSA   with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).
XNX-UTSV-NNIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, including MPD IR methane sensor   0-100%LEL (0-5%V/V).
XNX-UTSV-NHIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional local HART® interface   port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-UTSV-RNIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional alarm and fault relay   outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-UTSV-RHIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional alarm and fault relay   outputs and local HART ® interface port, including MPD IR methane sensor   0-100%LEL (0-5%V/V).
XNX-UTSV-MNIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Modbus® output, including   MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-UTSV-MHIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Modbus® output and local   HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V).
XNX-UTSV-FNIV1   XNX transmitter, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD IR methane sensor 0-5%V/V.
XNX-UTSV-FHIV1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD IR methane sensor   0-5%V/V.
XNX Aluminium Transmitter UL/CSA with MPD   Infrared CO2 Sensor 0-5%V/V.
XNX-UTAV-NNIC1   XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries,   painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v
XNX-UTAV-NHIC1   XNX Gas Detector, HART® over 4-20mA output and local HART® interface port,   UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2   sensor 0-5%v/v
XNX-UTAV-RNIC1   XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor   0-5%v/v
XNX-UTAV-RHIC1   XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD IR CO2 sensor 0-5%v/v
XNX-UTAV-MNIC1   XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x   3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v
XNX-UTAV-MHIC1   XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART®   interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes   MPD IR CO2 sensor 0-5%v/v
XNX-UTAV-FNIC1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA,   4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor   0-5%v/v
XNX-UTAV-FHIC1   XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local   HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium,   includes MPD IR CO2 sensor 0-5%v/v
XNX Stainless Steel Transmitter UL/CSA   with MPD Infrared CO2 Sensor 0-5%V/V.
XNX-UTSV-NNIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V.
XNX-UTSV-NHIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with local HART® interface port,   including MPD IR CO2 sensor 0-5%V/V.
XNX-UTSV-RNIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with alarm and fault relay outputs,   including MPD IR CO2 sensor 0-5%V/V.
XNX-UTSV-RHIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with alarm and fault relay outputs and   local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.
XNX-UTSV-MNIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with Modbus® output, including MPD IR   CO2 sensor 0-5%V/V.
XNX-UTSV-MHIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with Modbus® output and local HART®   interface port, including MPD IR CO2 sensor 0-5%V/V.
XNX-UTSV-FNIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output, including MPD IR CO2 sensor 0-5%V/V.
XNX-UTSV-FHIC1   XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT   entries, painted 316 stainless steel, with optional Foundation Fieldbus™   output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V.
SPARE MPD SENSORS
MPD: Multi-Purpose Detector (mV) - ATEX
MPD-AMCB1 XNX MPD ATEX/IEC SENSOR CAT   0-100%LEL
MPD-AMIV1 XNX MPD ATEX/IEC SENSOR IR CH4   0-100%LEL
MPD-AMIF1 XNX MPD ATEX/IEC SENSOR IR   0-100%LEL
MPD-AMIC1 XNX MPD ATEX/IEC SENSOR IR CO2   0-5%VV
MPD: Multi-Purpose Detector (mV) - UL/CSA
MPD-UTCB1 XNX MPD UL/CSA SENSOR CAT   0-100%LEL 
MPD-UTIV1 XNX MPD UL/CSA SENSOR IR CH4   0-100%LEL
MPD-UTIF1 XNX MPD UL/CSA SENSOR IR   0-100%LEL
MPD-UTIC1 XNX MPD UL/CSA SENSOR IR CO2   0-5%VV
SPARE MPD REPLACEABLE CARTRIDGES
1226A0359 XNX MPD CAT CARTRIDGE 0-100%LEL
1226-0300 XNX MPD IR CARTRIDGE 0-100%LEL
1226-0301 XNX MPD IR CARTRIDGE CO2 0-5%VV
1226-0299 XNX MPD IR CARTRIDGE CH4   0-100%LEL