Model 55-8xx
2015-06-17 23:17:52
Description:
Bimetal thermometer with switch contacts Stainless steel version……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
Description
Application
Control and regulation of industrial processes
Monitoring of plant and switching of electric circuits
Chemical industry, petrochemical industry, process technology and food industry
For aggressive medium
Special Features
High reliability and long service life
Universal application
Case and stem material stainless steel
Gauges with inductive contacts for use in hazardous areas with ATEX approval
Gauges with electronic contacts for PLC applications
Description
Wherever the process temperature has to be indicated locally, and, at the same time, circuits are to be made or broken, the bimetal thermometer with switch contact can be used.
Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted using a detachable adjustment key (mounted to the junction box) in the window.
Switch contacts consisting of several contacts can also be set to a single setpoint. Contact actuation is made when the actual value pointer travels beyond or below the desired set value.
As switch contacts sliding contacts, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.
For further information on the different switch contacts please see data sheet AC 08.01.