Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Honeywell SPXCDRSSH Sensor Socket Housing for XCD

Honeywell SPXCDRSSH Sensor Socket Housing for XCD

2018-03-19 11:45:40

Description:

The Sensepoint XCD (exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. This advanced and versatile range of gas detectors monitors and indicates the presence of any one of a selection of toxic and flammable gases. Any user can instantly identify the operating status of XCD via its clear multi-function backlit display. Output signals available are industrial standard 4 to 20mA, three relay contacts and MODBUS digital. A magnetic wand allows non intrusive one person calibration, while a wide choice of accesories means XCD can be used in many applications.……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Honeywell SPXCDRSSH Sensor Socket Housing for XCD


Sensepoint XCD


The Sensepoint XCD (exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. This advanced and versatile range of gas detectors monitors and indicates the presence of any one of a selection of toxic and flammable gases. Any user can instantly identify the operating status of XCD via its clear multi-function backlit display. Output signals available are industrial standard 4 to 20mA, three relay contacts and MODBUS digital. A magnetic wand allows non intrusive one person calibration, while a wide choice of accesories means XCD can be used in many applications.


Sensepoint XCD with Flammable and Primary Toxic Sensor Cartridge


A Sensepoint XCD KIT consists of Transmitter, Sensor socket, Sensor cartridge, Standard weather protection, Magnetic wand and Allen key.


Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)

Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. 

KIT includes Transmitter, Magnetic Wand and Allen Key


Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors)

Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors

such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored

from a convenient location.

KIT includes Transmitter, Magnetic Wand and Allen Key

Sensepoint   XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)
Sensepoint   XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider   selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be   fitted directly to the transmitter housing, or wired remotely from another   location. KIT includes Transmitter, Magnetic Wand and Allen Key
INSTRUMENT
Without   Modbus
SPXCDALMTX4   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20   Entries, 1 x M25 Entry, painted LM25
SPXCDASMTX4   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20   Entries, 1 x M25 Entry, painted 316SS
SPXCDULNTX4   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries,   painted LM25
SPXCDUSNTX4   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries,   painted 316SS
With   Modbus
SPXCDALMTX4M   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with   MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted LM25
SPXCDASMTX4M   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with   MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted 316SS
SPXCDULNTX4M   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4''   NPT Entries, painted LM25
SPXCDUSNTX4M   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4''   NPT Entries, painted 316SS
Note:   Refer to "Sensepoint" pricelist for the new M25 for ATEX/IECEx and   3/4''NPT for cCSA threaded range of Sensepoint Toxic sensors that may be   fitted directly to the 4-20mA input XCD-RTD transmitter.

Sensepoint   XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors)
Sensepoint   XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas   detectors such as Hi-Temperature version of Sensepint Flamable to be located   in adverse applications and monitored from a convenient location. KIT   includes Transmitter, Magnetic Wand and Allen Key
INSTRUMENT
Without   Modbus
SPXCDALMRFD   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted LM25
SPXCDASMRFD   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted 316SS
SPXCDULNRFD   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter, 3 x 3/4'' NPT Entries, painted LM25
SPXCDUSNRFD   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter, 3 x 3/4'' NPT Entries, painted 316SS
With   Modbus
SPXCDALMRFDM   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited LM25
SPXCDASMRFDM   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS
SPXCDULNRFDM   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25
SPXCDUSNRFDM   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS
Remote   Flammable Sensor (XCD Sensor Cartridge + Socket Housing)
SPXCDXSRFXSS   Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with   Socket Housing
SPXCDXSRRXSS   Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket   Housing
SPXCDXSRPXSS   Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket   Housing
SPXCDXSRB1SS   Carbon Dioxide IR 0-2.00%VOL only with Socket Housing Sensor Cartridge with   Socket Housing
SPXCDXSRB2SS   Carbon Dioxide IR 0-5.00%VOL only with Socket Housing Sensor Cartridge with   Socket Housing
00780-A-0100   Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX   certified)
Sensepoint XCD
ACCESSORIES, CONSUMABLES   & SPARES
ACCESSORIES
S3KCAL Calibration cap
SPXCDCC Collecting cone for   use with lighter than air gases
SPXCDDMK Duct mounting kit
SPXCDMTBR Mounting bracket   (inc. bolts, nuts, brackets)
SPXCDSDP Sunshade / Deluge   Protection
SPXCDFH Flow Housing for   Sample Panel
Consumables
SPXCDXSFXSS Flammable CAT   0-100%LEL (20,0 to 100.0%LEL)
SPXCDXSRXSS CH4(Methane) IR   0-100%LEL (20,0 to 100.0%LEL)
SPXCDXSPXSS C3H8 (Propane) IR   0-100%LEL (20,0 to 100.0%LEL)
SPXCDXSO1SS Oxygen 25.0%/Vol   only
SPXCDXSHXSS Hydrogen Sulfide   0-50ppm (10.0 to 100.0ppm)
SPXCDXSCXSS Carbon Monoxide   0-300ppm (100 to 1000ppm)
SPXCDXSG1SS Hydrogen   0-1000ppm only
SPXCDXSNXSS Nitrogen Dioxide   10-50ppm (10.0 to 50.0ppm)
SPXCDXSB1SS Carbon Dioxide IR   0-2%VOL only
SPXCDXSB2SS Carbon Dioxide IR   0-5%VOL only
Spares (Miscellaneous)
SPXCDWP Sensepoint XCD   Standard Weather Protection
SPXCDSRLS Sensor Retainer   with locking screw
SPXCDAKS Allen key for   stopper
SPXCDHWES Hex wrench for   earth screw
SPXCDEBS Earth Bracket and   Screws
SPXCDMAG Magnetic wand
SPXCDRSSH Sensor Socket   Housing for XCD
SPXCDMBUS Replacement Modbus   Module
SPXCDSERVK   Service Kit, Including O-ring front cover (2 pieces), Terminal module screw   (3
    pieces), Earth screw and bracket (2 pieces), O-ring weather housing, O-ring   cardridge
    retainer (2 pieces), O-ring on the cartridge (2 pieces), Locking screw for   front cover and
    sensor retainer (2 pieces)
SPXCDTOOLK   XCD Service Tool Kit, Including Magnet, Hex wrench for earth screw and Allen   key for locking screws
SPXCDTMK XCD Terminals Kit,   Including Terminal block for relays (green) and Terminal block power
SPXCDNPTP 3/4"NPT plug   (Certified as part of Ex d enclosure)
SPXCDM20P M20 plug (Certified   as part of Ex d enclosure)
Spares (Replacement Display   Module)
Each   replacement Display Module includes pre-configured PCB (for sensor and   range), backlit LCD and plastic housing. The unit is a plug in replacement   and simply requires confiiguration after fitting via the menu.
SPXCDDMT Replacement display   module for O2 & Toxic
SPXCDDMF Replacement display   module for FL & IR
SPXCDDM4 Replacement display   module for RTD (4~20mA)
SPXCDDMR Replacement display   module for RFD
SPXCDDMT12 Replacement O2   & Toxic display module Without Modbus for 12-32 Vdc
SPXCDDMF12 Replacement FL   & IR display module Without Modbus for 12-32 Vdc
SPXCDDMTM12 Replacement O2   & Toxic display module with Modbus for 12-32 Vdc
SPXCDDMFM12 Replacement FL   & IR display module with Modbus for 12-32 Vdc
SPXCDDMTM Replacement display   module for O2 & Toxic with Modbus
SPXCDDMFM Replacement display   module for FL & IR with Modbus
SPXCDDM4M Replacement display   module for RTD with Modbus
SPXCDDMRM Replacement display   module for RFD with Modbus
Spares (Replacement Terminal   Module)
Each   replacement terminal module includes pre-configured PCB (for sensor and   range), terminals, screws, 'U' clamp, plastic cover and fixing screws.
SPXCDTMO Replacement terminal   module for O2
SPXCDTMT Replacement terminal   module for Toxic
SPXCDTMF Replacement terminal   module for FL & IR
SPXCDTMO12 Replacement O2   terminal module for 12-32 Vdc
SPXCDTMT12 Replacement Toxic   terminal module for 12-32 Vdc
SPXCDTMF12 Replacement FL   & IR terminal module for 12-32 Vdc
SPXCDTM4 Replacement terminal   module for RTD (4~20mA)
SPXCDTMR Replacement terminal   module for RFD
Spares (ATEX APPROVAL   Replacement XCD STD version Transmitter only without MODBUS )
SPXCDALMTXO ATEX/IECEX &   AP approved SP XCD O2 Transmitter with LM25, M20 Entry
SPXCDALMTXT ATEX/IECEX &   AP approved SP XCD Toxic Transmitter with LM25, M20 Entry
SPXCDALMTXF ATEX/IECEX &   AP approved SP XCD FL/IR Transmitter with LM25, M20 Entry
SPXCDASMTXO ATEX/IECEX &   AP approved SP XCD O2 Transmitter with SS316, M20 Entry
SPXCDASMTXT ATEX/IECEX &   AP approved SP XCD Toxic Transmitter with SS316, M20 Entry
SPXCDASMTXF ATEX/IECEX &   AP approved SP XCD FL/IR Transmitter with SS316, M20 Entry
Spares (ATEX APPROVAL   Replacement XCD STD version Transmitter only with MODBUS )
SPXCDALMTXOM ATEX/IECEX &   AP approved SP XCD O2 Transmitter with LM25, M20 Entry
SPXCDALMTXTM ATEX/IECEX &   AP approved SP XCD Toxic Transmitter with LM25, M20 Entry
SPXCDALMTXFM ATEX/IECEX &   AP approved SP XCD FL/IR Transmitter with LM25, M20 Entry
SPXCDASMTXOM ATEX/IECEX &   AP approved SP XCD O2 Transmitter with SS316, M20 Entry
SPXCDASMTXTM ATEX/IECEX &   AP approved SP XCD Toxic Transmitter with SS316, M20 Entry
SPXCDASMTXFM ATEX/IECEX &   AP approved SP XCD FL/IR Transmitter with SS316, M20 Entry
Spares (UL APPROVAL   Replacement XCD STD version Transmitter only without MODBUS )
SPXCDULNTXO UL approved SP   XCD O2 Transmitter with LM25, 3/4"NPT Entry
SPXCDULNTXT UL approved SP   XCD Toxic Transmitter with LM25, 3/4"NPT Entry
SPXCDULNTXF UL approved SP   XCD FL/IR Transmitter with LM25, 3/4"NPT Entry
SPXCDUSNTXO UL approved SP   XCD O2 Transmitter with SS316, 3/4"NPT Entry
SPXCDUSNTXT UL approved SP   XCD Toxic Transmitter with SS316, 3/4"NPT Entry
SPXCDUSNTXF UL approved SP   XCD FL/IR Transmitter with SS316, 3/4"NPT Entry
Spares (UL APPROVAL   Replacement XCD STD version Transmitter only with MODBUS )
SPXCDULNTXOM UL approved SP   XCD O2 Transmitter with LM25, 3/4"NPT Entry
SPXCDULNTXTM UL approved SP   XCD Toxic Transmitter with LM25, 3/4"NPT Entry
SPXCDULNTXFM UL approved SP   XCD FL/IR Transmitter with LM25, 3/4"NPT Entry
SPXCDUSNTXOM UL approved SP   XCD O2 Transmitter with SS316, 3/4"NPT Entry
SPXCDUSNTXTM UL approved SP   XCD Toxic Transmitter with SS316, 3/4"NPT Entry
SPXCDUSNTXFM UL approved SP   XCD FL/IR Transmitter with SS316, 3/4"NPT Entry

Special Flammable Gas   Calibrations
SPXCDSFGC1 Special Flammable   Gas Calibration, 0-100%LEL
SPXCDSFGC2 Special Flammable   Gas Calibration, 0-100%LEL
SPXCDSFGC3 Special Flammable   Gas Calibration, 0-100%LEL
SPXCDSFGC4 Special Flammable   Gas Calibration, 0-100%LEL
SPXCDSFGC5 Special Flammable   Gas Calibration, 0-100%LEL
SPXCDSFGC6-H Special   Flammable Gas Calibration, 0-100%LEL,6* - Hydrogen
SPXCDSFGC7 Special Flammable   Gas Calibration, 0-100%LEL
SPXCDSFGC8 Special Flammable   Gas Calibration, 0-100%LEL
Note:   If no Special Flammable Gas Calibration part no. is included on PO, a Methane   (6* calibration will be supplied)