
Honeywell Remote Flammable Sensor SPXCDXSRFXSS
2018-03-12 17:14:03
Description:
Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing……
New Products
Orbinox VG SERIES 61 Slurry knife gate valve
Orbinox SERIES 61 (VG) model knife gate valve is a wafer type valve equipped with two metal reinforced rubber sleeves,designed for applications with abrasive slurries.
Crosby J-Series Direct Spring Pressure Relief Valves
J-Series valves provide high quality and dependable overpressure protection for air, gas, steam, vapor, liquid and two-phase applications in one simple design. Now available with two new to the world technologies, Balanced Diaphragm and Bellows Leak Detection.
Vanessa Series 30,000 Cryogenic Triple Offset Valve
The Vanessa Series 30,000 Cryogenic Triple Offset Valve is a virtually maintenance-free valve with tightness, operability and torque demand unaffected by cryogenic conditions and severe temperature fluctuations.
Sempell Model SOT High pressure steam safety valve
The Sempell Model SOT is a high-pressure steam safety valve designed for boiler protection and steam system safety.
Assortments
Description
Honeywell Remote Flammable Sensor SPXCDXSRFXSS
Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing
Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)
Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location.
KIT includes Transmitter, Magnetic Wand and Allen Key
Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors)
Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors
such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored
from a convenient location.
KIT includes Transmitter, Magnetic Wand and Allen Key
Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors) |
Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. KIT includes Transmitter, Magnetic Wand and Allen Key |
INSTRUMENT |
Without Modbus |
SPXCDALMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted LM25 |
SPXCDASMTX4 ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20 Entries, 1 x M25 Entry, painted 316SS |
SPXCDULNTX4 cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNTX4 cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries, painted 316SS |
With Modbus |
SPXCDALMTX4M ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted LM25 |
SPXCDASMTX4M ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted 316SS |
SPXCDULNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS |
Note: Refer to "Sensepoint" pricelist for the new M25 for ATEX/IECEx and 3/4''NPT for cCSA threaded range of Sensepoint Toxic sensors that may be fitted directly to the 4-20mA input XCD-RTD transmitter. |
Sensepoint XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors) |
Sensepoint XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas detectors such as Hi-Temperature version of Sensepint Flamable to be located in adverse applications and monitored from a convenient location. KIT includes Transmitter, Magnetic Wand and Allen Key |
INSTRUMENT |
Without Modbus |
SPXCDALMRFD ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted LM25 |
SPXCDASMRFD ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted 316SS |
SPXCDULNRFD cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNRFD cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter, 3 x 3/4'' NPT Entries, painted 316SS |
With Modbus |
SPXCDALMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited LM25 |
SPXCDASMRFDM ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS |
SPXCDULNRFDM cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25 |
SPXCDUSNRFDM cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS |
Remote Flammable Sensor (XCD Sensor Cartridge + Socket Housing) |
SPXCDXSRFXSS Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
SPXCDXSRRXSS Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
SPXCDXSRPXSS Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket Housing |
SPXCDXSRB1SS Carbon Dioxide IR 0-2.00%VOL only with Socket Housing Sensor Cartridge with Socket Housing |
SPXCDXSRB2SS Carbon Dioxide IR 0-5.00%VOL only with Socket Housing Sensor Cartridge with Socket Housing |
00780-A-0100 Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX certified) |