Top Industrial Automation and Electrical Instrument from HKXYTECH
  • Honeywell SPXCDUSNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS

Honeywell SPXCDUSNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS

2018-03-08 16:28:07

Description:

Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)……

Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. KIT includes Transmitter, Magnetic Wand and Allen Key

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

Honeywell SPXCDUSNTX4M cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS


Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)


Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location. KIT includes Transmitter, Magnetic Wand and Allen Key

Sensepoint   XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors)
Sensepoint   XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider   selection of 2-wire 4 to 20 mA input type Toxic and Oxygen sensors to be   fitted directly to the transmitter housing, or wired remotely from another   location. KIT includes Transmitter, Magnetic Wand and Allen Key
INSTRUMENT
Without   Modbus
SPXCDALMTX4   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20   Entries, 1 x M25 Entry, painted LM25
SPXCDASMTX4   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter, 2 x M20   Entries, 1 x M25 Entry, painted 316SS
SPXCDULNTX4   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries,   painted LM25
SPXCDUSNTX4   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter, 3 x 3/4'' NPT Entries,   painted 316SS
With   Modbus
SPXCDALMTX4M   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with   MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted LM25
SPXCDASMTX4M   ATEX, IECEx & AP approved SP XCD-RTD 4~20mA Input Transmitter with   MODBUS, 2 x M20 Entries, 1 x M25 Entry, painted 316SS
SPXCDULNTX4M   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4''   NPT Entries, painted LM25
SPXCDUSNTX4M   cCSAus approved SP XCD-RTD 4~20mA Input Transmitter with MODBUS, 3 x 3/4''   NPT Entries, painted 316SS
Note:   Refer to "Sensepoint" pricelist for the new M25 for ATEX/IECEx and   3/4''NPT for cCSA threaded range of Sensepoint Toxic sensors that may be   fitted directly to the 4-20mA input XCD-RTD transmitter.

Sensepoint   XCD-RFD transmitter (use with Standard & Hi-Temp Sensepoint sensors)
Sensepoint   XCD-RFD (Remote Flammable Detector) allows for remotely mounted flammable gas   detectors such as Hi-Temperature version of Sensepint Flamable to be located   in adverse applications and monitored from a convenient location. KIT   includes Transmitter, Magnetic Wand and Allen Key
INSTRUMENT
Without   Modbus
SPXCDALMRFD   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted LM25
SPXCDASMRFD   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter, 2 x M20 Entries,1 x M25 Entry,painted 316SS
SPXCDULNRFD   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter, 3 x 3/4'' NPT Entries, painted LM25
SPXCDUSNRFD   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter, 3 x 3/4'' NPT Entries, painted 316SS
With   Modbus
SPXCDALMRFDM   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited LM25
SPXCDASMRFDM   ATEX, IECEx & AP approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor   input Transmitter with MODBUS, 2 x M20 Entries, 1 x M25 Entry, paited 316SS
SPXCDULNRFDM   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted LM25
SPXCDUSNRFDM   cCSAus approved SP XCD-RFD Remote Flammable (Cat or IR) Sensor input   Transmitter with MODBUS, 3 x 3/4'' NPT Entries, painted 316SS
Remote   Flammable Sensor (XCD Sensor Cartridge + Socket Housing)
SPXCDXSRFXSS   Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with   Socket Housing
SPXCDXSRRXSS   Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket   Housing
SPXCDXSRPXSS   Propane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Sensor Cartridge with Socket   Housing
SPXCDXSRB1SS   Carbon Dioxide IR 0-2.00%VOL only with Socket Housing Sensor Cartridge with   Socket Housing
SPXCDXSRB2SS   Carbon Dioxide IR 0-5.00%VOL only with Socket Housing Sensor Cartridge with   Socket Housing
00780-A-0100   Term Hsg-Bartec DE1155 With Continuity Plate 1x25mm- 3x20mm Entries (ATEX   certified)