Top Industrial Automation and Electrical Instrument from HKXYTECH
  • UD320 Manual Setter

UD320 Manual Setter

2016-09-18 14:59:47

Description:

The UD310 manual setter has PV display, and transmit 4 to 20 mA DC by manual operation.It can be used as a remote setter for digital indicating controllers like UTAdvanced series controllers. The SP (target setpoint) will be output in 3 seconds after the change. The TC, RTD or Voltage input is possible as PV input. When the PV display is not necessary, it can be disappeared. The two alarm outputs and a PV retransmission output are provided as standard. The front panel has a splash-proof and dust-proof design (IP65), which enables the use in the dusty environment. ……

Notice:

New Products

Allen-Bradley 25B-V4P8N104 PowerFlex 525 low voltage AC drives - Rockwell

Allen-Bradley 25B-V4P8N104 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 120 VAC, 1 Phase, 4.8 Amps, 1.0 HP, 0.75 kW Normal Duty; 1.0 HP, 0.75 kW Heavy Duty, Frame B, IP20 NEMA / Open Type, No Filter.

Allen-Bradley 25B-V6P0N104 PowerFlex 525 low voltage AC drives - Rockwell

Allen-Bradley 25B-V6P0N104 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 120 VAC, 1 Phase, 6 Amps, 1.5 HP, 1.1 kW Normal Duty; 1.5 HP, 1.1 kW Heavy Duty, Frame B, IP20 NEMA / Open Type, No Filter.

Allen-Bradley 25B-D4P0N114 PowerFlex 525 low voltage AC drives - Rockwell

Allen-Bradley 25B-D4P0N114 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 480 VAC, 3 Phase, 4 Amps, 2 HP, 1.5 kW Normal Duty; 2 HP, 1.5 kW Heavy Duty, Frame A, IP20 NEMA / Open Type, Filter.

Allen-Bradley 25B-D6P0N104 PowerFlex 525 low voltage AC drives - Rockwell

Allen-Bradley 25B-D6P0N104 PowerFlex 525 AC Drive, with Embedded EtherNet/IP and Safety, 480 VAC, 3 Phase, 6 Amps, 3 HP, 2.2 kW Normal Duty; 3 HP, 2.2 kW Heavy Duty, Frame A, IP20 NEMA / Open Type, No Filter.

Assortments

Description

Overview

UD320 manual setter 

The UD310 manual setter has PV display, and transmit 4 to 20 mA DC by manual operation.It can be used as a remote setter for digital indicating controllers like UTAdvanced series controllers. The SP (target setpoint) will be output in 3 seconds after the change. The TC, RTD or Voltage input is possible as PV input. When the PV display is not necessary, it can be disappeared. The two alarm outputs and a PV retransmission output are provided as standard. The front panel has a splash-proof and dust-proof design (IP65), which enables the use in the dusty environment.