Models 112.28, 132.28 Bourdon tube pressure gauge Industrial series
2015-06-17 21:10:57
Description:
Models 112.28, 132.28 Bourdon tube pressure gauge Industrial series……
Notice:
New Products
Emerson TREXCHPKL9S1 AMS Trex device communicator
Emerson TREXCHPKL9S1 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Standard support 1 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3S AMS Trex device communicator
Emerson TREXCHPKLWP3S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP3 AMS Trex device communicator
Emerson TREXCHPKLWP3 AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 3 year. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Emerson TREXCHPKLWP1S AMS Trex device communicator
Emerson TREXCHPKLWP1S AMS Trex device communicator. HART Application, ATEX, CSA US/Canada and IECEx intrinsically safe, Wireless, Premium support 1 year, Carrying Case. Enables HART or Fieldbus Module device communications, 5.7 inch touchscreen display, intrinsically safe.
Assortments
Description
Applications
For gaseous and liquid media that are not highly viscous or crystallising
Model 112.28: Measuring system Cu-alloy
Model 132.28: Measuring system stainless steel, also for aggressive mediaHydraulics
Compressors
Refrigeration technology
Special features
Vibration and shock resistant Especially sturdy design Stainless steel case Scale ranges up to 0 … 40 bar
Description
Design
EN 837-1
Nominal size in mm
80
Accuracy class
1.6
Scale ranges
Model 112.28: 0 ... 0.6 to 0 ... 40 bar
Model 132.28: 0 ... 1 to 0 ... 40 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient:
-40 ... +60 °C
Medium:
+60 °C maximum (model 112.28)
+200 °C maximum (model 132.28)
Temperature effect
When the temperature of the measuring system deviates
from the reference temperature (+20 °C):
Max. ±0.4 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529