Model 111.10-hkxytech
  • Model 111.10

Model 111.10

2015-06-18 12:10:06

Description:

Bourdon tube pressure gauge Lower mount, standard version……

Notice:

New Products

E+H FMU90-R11CA111AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90

E+H FMU90-R11CA111AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90. Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.

E+H FMU90-R11CA131AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90

E+H FMU90-R11CA131AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90. Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.

E+H FMU90-R11CA212AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90

E+H FMU90-R11CA212AA3A Ultrasonic Level measurement, Endress+Hauser Prosonic FMU90. Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.

E+H FMU42-APB2A22A Ultrasonic Sensor, Endress+Hauser Prosonic FMU42

E+H FMU42-APB2A22A Ultrasonic Sensor, Endress+Hauser Prosonic FMU42. Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m.

Assortments

Description

Applications

  • For gaseous and liquid media that are not highly viscous or crystallising and will not attack copper alloy parts

  • Pneumatics

  • Heating and air-conditioning technology

  • Medical engineering


Special Features

  • Reliable and cost-effective

  • Design per EN 837-1

  • Nominal size 40, 50, 63, 80, 100 and 160

  • Scale ranges up to 0 ... 400 bar


Descriptions

Design
EN 837-1

Nominal size in mm
40, 50, 63, 80, 100 and 160

Accuracy class
2.5

Scale ranges
0 ... 0.6 to 0 ... 400 bar (NS 160: max. 40 bar)
or all other equivalent vacuum or combined pressure and vacuum ranges

Pressure limitation
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value

Permissible temperature
Ambient: -20 ... +60 °C
Medium: +60 °C maximum

Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span