YOKOGAWA ESD Analog Input Module SAI143-S53-hkxytech
  • YOKOGAWA  ESD Analog Input Module SAI143-S53
  • YOKOGAWA  ESD Analog Input Module SAI143-S53
  • YOKOGAWA  ESD Analog Input Module SAI143-S53

YOKOGAWA ESD Analog Input Module SAI143-S53

2016-06-13 15:07:38

Description:

YOKOGAWA ESD SAI143-S53 This GS describes the hardware specifications of the analog I/O modules that can be mounted on the safety node unit and the safety control unit.……

Notice:
YOKOGAWA ESD SAI143-S53 Place of Origin: Singapore,Yokogawa original packing, by carton

New Products

Honeywell STA700 SmartLine Absolute Pressure STA72L-F1G000-1-0-AHB-11S-A-10A0

Introduction Part of the SmartLine® family of products, the STA700 and STA70L are suitable for monitoring, control and data acquisition. STA70X products feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation capabilities providing high accuracy, stability and performance over a wide range of application pressures and temperatures.

Honeywell STA700 SmartLine Absolute Pressure ​STA722/STA725/STA72L/STA72S

Introduction Part of the SmartLine® family of products, the STA700 and STA70L are suitable for monitoring, control and data acquisition. STA70X products feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation capabilities providing high accuracy, stability and performance over a wide range of application pressures and temperatures.

Honeywell SmartLine Absolute Pressure ​STA722-E1GC4A-1-0-AH0-11S-A-00A0​

Introduction Part of the SmartLine® family of products, the STA700 and STA70L are suitable for monitoring, control and data acquisition.

Honeywell STA700 SmartLine Absolute Pressure

Part of the SmartLine® family of products, the STA700 and STA70L are suitable for monitoring, control and data acquisition. STA70X products feature piezoresistive sensor technology combining pressure sensing with on chip temperature compensation capabilities providing high accuracy, stability and performance over a wide range of application pressures and temperatures.

Assortments

Description

YOKOGAWA ESD Analog Input Module SAI143-S53 


n STANDARD SPECIFICATIONS

 

l Current Input Module

 

This module inputs 4 to 20 mA signals from the field.

 

The SAI143 can be made dual redundant.

 


Item

Specifications


Model


SAI143 (*1)


Number of input channels

16-channel, module isolation (*5)


Rated input range

4 to 20 mA


Permissible input range

0 to 25 mA


Input impedance during Power-ON

250 Ω+ Voltage drop in the   input protection circuit inside the module

(*6)



Current value





Input impedance during Power-OFF

500 kΩ minimum


Rated accuracy

SAI143-S : ±16 µA (Input range 1 to 23 mA)


SAI143-H : ±16 µA (Input range 0.05 to 23 mA)   (*3) (*4)





Data update frequency

40 ms


Temperature drift

±16 µA/10 °C


Transmitter power supply

16.15 V minimum (at 20 mA)


26.4 V maximum (at 0 mA)




(Output current limit: 25 mA)






2/4-wire setting

Individual channel setting


Changed by setting pins








Withstand voltage

1.5 kV AC between input signal and system for   1 minute (*2)


Maximum current consumption

5 V system: 320 mA,


24 V system: 550 mA





Weight


Approx. 0.34 kg (For pressure clamp terminal   block or MIL cable)



Approx. 0.39 kg (With signal cable interface   adapter)









External connection

Pressure clamp terminal


MIL cable




Dedicated signal cable





Support PRM

Available (SAI143-H)



YOKOGAWA ESD Analog Input Module SAI143-S53 


 MODEL AND SUFFIX CODES



Description

Model

SAI143

Analog Input Module (4 to 20 mA, 16-channel, module isolation)

 

 

 

 

 

Suffix Codes

-S

Standard type

-H

With HART communication [Release: R1.02.00] (*1)

5

For pressure clamp terminal block or MIL cable with no explosion protection

6

With signal cable interface adapter and no explosion protection (*2)

E

For pressure clamp terminal block or MIL cable with explosion protection

F

With signal cable interface adapter and explosion protection (*2)

3

With ISA Standard G3 and temperature (-20 to 70 ºC)

C

With ISA Standard G3 and high-density installation (-20 to 70 ºC) (*5)

 

 

 

 

 

 

Option Codes

 

/A4S00

With pressure clamp terminal block for analog

[Model: STA4S-00]

 

/A4S10

With pressure clamp terminal block for analog (with surge absorber) [Model: STA4S-10]

 

/A4D00

With dual-redundant pressure clamp terminal block for analog (*3) [Model: STA4D-00]

 

/A4D10

With dual-redundant pressure clamp terminal block for analog (with surge absorber) (*3) [Part name: STA4D-10]

/PRP

With prevention pin of false insertion (*4)

 

/CCC01

With connector cover for MIL cable (for flat ribbon cable) [Model: SCCC01]




ORDERING INFORMATION

Specify the model and suffix codes.

For selecting the right products for explosion protection, please refer to TI 32S01J30-01E without fail.


SAI143 Analog Input Module (4 to 20 mA, 16-channel, module isolation)

SAI143-S53/A4S00 , SAI143-S53/A4S10 , SAI143-S53/A4D00 , SAI143-S53/A4D10 ,SAI143-S53/PRP, SAI143-S53/CCC01

SAI143-S63/A4S00 , SAI143-S63/A4S10 , SAI143-S63/A4D00 , SAI143-S63/A4D10 ,SAI143-S63/PRP, SAI143-S63/CCC01

SAI143-SE3/A4S00 , SAI143-SE3/A4S10 , SAI143-SE3/A4D00 , SAI143-SE3/A4D10 ,SAI143-SE3/PRP, SAI143-SE3/CCC01

SAI143-SF3/A4S00 , SAI143-SF3/A4S10 , SAI143-SF3/A4D00 , SAI143-SF3/A4D10 ,SAI143-SF3/PRP, SAI143-SF3/CCC01

SAI143-S5C/A4S00 , SAI143-S5C/A4S10 , SAI143-S5C/A4D00 , SAI143-S5C/A4D10 ,SAI143-S5C/PRP, SAI143-S5C/CCC01

SAI143-S6C/A4S00 , SAI143-S6C/A4S10 , SAI143-S6C/A4D00 , SAI143-S6C/A4D10 ,SAI143-S6C/PRP, SAI143-S6C/CCC01

SAI143-SEC/A4S00 , SAI143-SEC/A4S10 , SAI143-SEC/A4D00 , SAI143-SEC/A4D10 ,SAI143-SEC/PRP, SAI143-SEC/CCC01

SAI143-SFC/A4S00 , SAI143-SFC/A4S10 , SAI143-SFC/A4D00 , SAI143-SFC/A4D10 ,SAI143-SFC/PRP, SAI143-SFC/CCC01