Top Industrial Automation and Electrical Instrument from HKXYTECH
  • EJA115E Low Flow Transmitter
  • EJA115E Low Flow Transmitter

EJA115E Low Flow Transmitter

2016-05-06 02:04:47

Description:

The low flow transmitter EJA115E is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. It outputs a 4 to 20 mA DC signal corresponding to the measured flow. Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available. All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.……

New Products

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0DH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature New load group, width: 22.5 mm.

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA

Siemens 6DL1193-6TP00-0BH1 SIMATIC ET 200SP HA, Terminal block, Type H1, 32 push-in terminals, internal reference temperature Width: 22.5 mm.

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GC00-0NN0 SIMATIC ET 200SP HA, carrier module 8-fold carrier for holding 8 I/O modules of the ET 200SP HA.

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA

Siemens 6DL1193-6GA00-0NN0 SIMATIC ET 200SP HA, carrier module 2-fold carrier for holding 2 I/O modules of the ET 200SP HA.

Assortments

Description

EJA115E Low Flow Transmitter



EJA115E

The low flow transmitter EJA115E is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. It outputs a 4 to 20 mA DC signal corresponding to the measured flow. Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available. All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.

  • 0.055% Accuracy (0.04% Accuracy option)

  • 0.1% Stability for 7 years

  • MWP 2,300 psi (MWP 3,600 psi option)

  • 90 ms Response Time

  • Local Parameter Setting (LPS)

  • SIL 2 (IEC 61508) Certified

  


The EJA115E is Differential Pressure Transmitter in the series that is optimized for low flow applications with the addition of an Integral Flow Orifice (IFO).

EJA115E features include:

  • 0.055% Square Root Output Accuracy

  • 0.1% per 7 years Stability (DP)

  • Exida and TUV SIL 2/3 Certified

  • 90 ms ~ 150 ms Response Time

  • Local Parameter Setting (LPS)

Available with HART 5/7, 1 to 5 VDC HART 7 (Low Power), FOUNDATION Fieldbus, PROFIBUS PA, BRAIN communication.


 

 

Selection Table

Selection Table

ModelApplicationTypeCapsuleMeasurement SpanMaximum Working Pressure
kPainH2OMPapsi
EJA110EDifferential
Pressure
Traditional-
Mounting*1
F
M
H
V
0.5 to 5
1 to 100
5 to 500
0.14 to 14 MPa
2 to 20
4 to 400
20 to 2000
20 to 2000 psi
16
16
16
16
2300
2300
2300
2300
EJA115EFlowIntegral
Orifice
F
M
H
1 to 5
2 to 100
20 to 210
4 to 20
8 to 400
80 to 830
16
16
16
2300
2300
2300
EJA118EDifferential
Pressure
& Liquid
Level
with 
Remote
Seals
Extended
Flush
Combination
M
H
2.5 to 100
25 to 500
10 to 400
100 to 2000
Based on Flange Rating
EJA120EDraft
Range
Traditional-
Mounting*1
E0.1 to 10.4 to 450 kPa7.25
EJA130EDifferential
Pressure
& Liquid
Level
Traditional-
Mounting*1
M
H
1 to 100
5 to 500
4 to 400
20 to 2000
32
32
4500
4500
EJA210ELiquid
Level,
(Closed
or Open
Tank)
Flush
Extended
M
H
1 to 100
5 to 500
4 to 400
20 to 2000
Based on Flange Rating
EJA310EAbsolute
(Vacuum)
Pressure*2
Traditional-
Mounting*1
L
M
A
B
0.67 to 10
1.3 to 130
0.03 to 3.5 MPa
0.14 to 16 MPa
0.2 to 2.95 inHg
0.39 to 38 inHg
4.3 to 500 psi
20 to 2300 psi
10 kPa
130 kPa
3.5
16
2.95 inHg
38 inHg
500
2300
EJA430EGauge
Pressure
Traditional-
Mounting*1
H
A
B
5 to 500
0.03 to 3.5 MPa
0.14 to 16 MPa
20 to 2000
4.3 to 500 psi
20 to 2300 psi
500 kPa
3.5
16
2000 inH2O
500
2300
EJA438EGauge
Pressure
with Remote
Seal
FlushA
B
0.06 to 3.5 MPa
0.46 to 16 MPa
8.6 to 500 psi
66 to 2300 psi
Based on Flange Rating
ExtendedA
B
0.06 to 3.5 MPa
0.46 to 7 MPa
8.6 to 500 psi
66 to 1000 psi
EJA440EHigh
Gauge
Traditional-
Mounting*1
C
D
5 to 32 MPa
5 to 50 MPa
720 to 4500 psi
720 to 7200 psi
32
50
4500
7200
EJA510E
EJA530E
Absolute
& Gauge
Pressure*2
Direct-
Mounting
A
B
C
D
10 to 200
0.1 to 2 MPa
0.5 to 10 MPa
5 to 50 MPa
1.45 to 29 psi
14.5 to 290 psi
72.5 to 1450 psi
720 to 7200 psi
200 kPa
2
10
50
29
290
1450
7200
*1:Traditional-Mounting is 1/4NPT or Rc1/4 process connections (1/2NPT or Rc1/2 with process adapter).
*2:Measurement values in Absolute for Absolute Pressure Transmitter.

Why do you choose us?
1. 100% original yokogawa product, 100% quality assurance. 
If you find a fake yokogawa. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt  L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!